SEAL AQUA AS-1600 사용자 설명서

다운로드
페이지 20
 
Section 2.  Operating Procedures 
 
 
11 
All operating functions are initiated at the control panel.  The following section 
outlines general procedures and describes specific functions used to coat media.  
This section is divided into the following sub-headings: 
1.  Loading Materials 
2.  Pre-heat the laminator 
3.  Web the laminator 
4.  Run the laminator 
5.  Cleaning the laminator 
Tools/Supplies Required: 
• 
Absorbent towels:  soft, lint free, disposable 
• 
Lab coat or smock 
• 
Rubber gloves 
• 
Bucket of water 
• 
3M Scotchbrite pad 
1.  Loading Materials 
Loading the Sealant: 
1.  Disconnect quick-connector fitting in supply line and remove the lid from the 
Sealant Tank.  
 
 
Figure 2.1 Quick Disconnect 
 
2.  Pour  AquaSEAL™ 110 or  AquaSEAL™ 510 into the Sealant Tank. The sealant 
tank holds 18 Liters (5 US gallons) of sealant.  (Be careful not to add too much 
sealant to the tank.) 
3.  Position Sealant Tank onto the tank pedestal and reattach the quick-connector 
fitting in the supply line. (Ensure that the Flow control valve is closed) 
4.  Using rolled media, position the roll on the Unwind Mandrel.  The media must be 
oriented to feed into the machine with the image side up.