Several issues must be addressed when selecting a suitable location for your 
W3000 wood stove. Observing required clearances to combustible materials, the 
proximity to a safe chimney, and electrical supply (if optional blower in use) must all 
be considered. In addition, selecting a location that takes advantage of the building’s 
natural air flow is also desirable to maximize the heating effectiveness of the heater. 
In many cases, this is a central location within the building. 
 
SPECIFICATIONS 
 
FREESTANDING: 
Width: 26” 
Height: 29 ½” 
Depth: 21 ¾” (total - from face) 
Weight: 430 lbs. 
Flue size: 6” 
EPA status: Non-Catalytic – 2.28 Grams Per Hour 
Burn time: 7 – 9 hours 
BTU range: 9,500 to 37,000 BTU’s/hr 
Approved installations: 
FIREPLACE INSERT: 
Width: 22 7/8” (at fireplace rear) 
           26” (at fireplace opening) 
Height: 20” (in fireplace)  
Depth: 21 ¼” (total – from face) 
           12 ¾” (in fireplace) 
Flashing Size: 40 ½” W x 26 5/8” H (medium) 
 
       48 ½” W x 30 5/8” H (large) 
Weight: 430 lbs. 
 
Flashing: 13 lbs. 
Flue size: 6” 
EPA status: Non-Catalytic – 2.28 Grams Per Hour 
Burn time: 7 – 9 hours 
BTU range: 9,500 to 37,000 BTU’s/hr 
Approved installations: zero-clearance, masonry 
 
CLEARANCES 
 
W3000FS 
 
The stove must be placed on a continuous (grouted joints) noncombustible material 
such as ceramic tile, cement board, brick, 3/8” millboard or equivalent ½” material 
with a k+ .84 insulation factor, or other approved or listed material suited for floor 
protection. Check local codes for approved alternatives. Clearances for floor 
protection are measured from the sides, back, and face (door opening) as shown in 
figure 1. 
 
Minimum clearance to combustibles must be maintained as shown in figure 2 and 
the following chart. 
 
 
B* 
D* 
E* 
Single Wall 
Connector 
 
24” 
 
14” 
 
16” 
 
14” 
 
7” 
 
16” 
 
84” 
 
30” 
Double Wall 
Connector 
 
22” 
 
12 ½” 
 
12” 
 
10” 
 
7” 
 
16” 
 
84” 
 
30” 
Alcove with 
Double Wall 
 
22” 
 
12 ½” 
 
12” 
 
10” 
 
7” 
 
16” 
 
84” 
 
30” 
Mobile Home 
Double Wall 
 
22” 
 
12 ½” 
 
12” 
 
10” 
 
7” 
 
16” 
 
84” 
 
30” 
 
*Given for reference only. Always maintain the clearances listed to the pipe. 
 
W3000I 
 
Minimum clearances to combustibles must be maintained as shown in figure 3 and 
the following chart. NOTE: Materials projecting more than ¾” from the wall are 
considered mantels. 
 
 
W3000I 
24” 
32” 
18” 
9” 
19 15/16” 
4 9/16” 
8 ½” 
12 5/8” 
W3000I 
w/Heat Shield* 
 
16” 
 
24” 
 
18” 
 
9” 
 
19 15/16” 
 
4 9/16” 
 
8 ½” 
 
12 5/8” 
 
*Use only the Breckwell Heat Shield – Part Number CW-S-157. 
The floor in front of the stove must be protected as 
shown in figure 2 and as listed below. The floor 
protection must also extend 8” to either side of the 
door opening. 
 
When hearth protection is a minimum of 2” high (Q), 
The depth (R) must be a minimum of 24” 
 
When hearth protection is a minimum of 4” high (Q), 
The depth (R) must be a minimum of 21” 
 
When hearth protection is a minimum of 6” high (Q), 
The depth (R) must be a minimum of 18” 
 
When the stove is installed in factory built fireplaces, 
2” of clearance must be maintained under the 
portion of the insert that extends out over the hearth 
extension. 
DO NOT USE MAKESHIFT MATERIALS OR 
COMPROMISES IN THE INSTALLATION OF THIS 
UNIT. 
INSTALL VENT  WITH CLEARANCES SPECIFIED 
BY THE VENT MANUFACTURER. 
 
 
 
 
 
 
 
 
 
 
 
 
INSTALLATION 
FIGURE 1 
FIGURE 2