Maintenance
© Travis Industries
4080123
100-01174_002
Maintaining Your Heater's Appearance
Fingerprints  or  other  marks  left  on  the  optional  plated  surface  may  become  etched  in  place  if  they
are  not  wiped  clean  prior  to  turning  the  heater  on.    Clean  the  plated  surfaces  with  denatured
alcohol  and  a  soft  cloth  (with  the  heater  cool).    Other  cleaners  may  leave  a  film  that  may  become
etched  into  the  surface.
Yearly Service Procedure
 
Failure to inspect and maintain the heater may lead to improper combustion and a potentially dangerous
situation.  We recommend the following procedures be done by a qualified technician.
1.  Check the pilot flame.  It should touch approximately 3/8" of the top of the thermopile and touch the top of
the  thermocouple  (see  illustration  below).    If  it  does  not,  contact  your  dealer  for  service.
2.  Shut off gas to the heater by turning the gas control knob to "OFF" (see step A under "Starting the Pilot" on
page  27).  Let the heater cool for 15 minutes.  Remove the face (see the instructions included with the face)
and glass (see page 20).
3.  Remove the log set (NOTE: the logs are very fragile - see page 22).  If severely deteriorated, replace.
Check  the  logs  for  sooting.    A  small  amount  of  soot  along  the  bottom  of  the  logs  is  normal.    If  excessive
sooting is found, the heater will require adjustment.  Contact your dealer.
4.  Clean the burner (especially the burner holes) and inspect the following:
 
Make sure the burner is not warped, cracked, or damaged.
 
Check the firebox and area around the pilot to make sure there is no warping or damage.
 
If  any  problem  is  found,  discontinue  use  and  contact  your  dealer  for  service.
A
A
A
A
A
Check the burner holes.
Make sure the 
burner is not 
warped or 
damaged.
Check the walls and ceiling of the firebox for 
deterioration.
Thermopile
Pilot Hood
Thermocouple
Before Disassembly - 
Check the pilot flame.  It 
should touch the 
thermocouple and 
thermopile.
5.  Replace the log set.  Clean and replace the glass (use non-abrasive cleaner - if damaged, replace).  Make
sure the gasket along the perimeter of the glass contacts the face of the firebox and forms an air-tight seal.
If it does not, re-align or replace the gasket to insure an air-tight seal.  Replace the faceplate.
6.  Inspect the area behind the access door. Check the gas control valve and the gas lines.  If damage is
found,  discontinue  use  and  contact  your  dealer  for  service.    Clean  the  air  channels,  ducts,  and  the  area
around the blower.
7.  Start the pilot and turn on the main burner.  The flames should be orange/yellow and not touch the top of the
firebox.  If the pilot or main burners do not burn correctly, contact your dealer for service.  Monitor the
blower operation.
8.  Remove  any  debris  or  vegetation  near  the  vent  termination.    Contact  your  dealer  if  any  sooting  or
deterioration  is  found  near  the  vent  termination.