Troubleshooting  Table
Problem:
Possible Cause:
Don't Call for Service
Until You:
Pilot Will Not Light
A  gas  shut  off  valve  is  turned  off                    
The gas control knob isn't turned to "PILOT"      
The valve control knob isn't pushed in              
The igniter wasn't pressed repeatedly               
No Propane in Tank                                       
Check  all  gas  shut  off  valves
See "Starting the Pilot Light" Step C
See "Starting the Pilot Light" Step C
See "Starting the Pilot Light" Step C
Check Tank Level
Main Burners Will
Not Start
The pilot light has gone out                             
The gas control valve is turned to "PILOT" or "OFF"
The ON/OFF switch is turned to "OFF"             
The remote control is not working correctly        
The thermostat is disconnected or set too low   
See "Starting the Pilot Light"
See "Starting the Pilot Light"
Turn the ON/OFF switch to "ON"
See  the  remote  control  instructions
See "Thermostat Operation"
Remote Control
Does Not Work
The pilot light has gone out                             
The gas control valve is turned to "PILOT" or "OFF"
The ON/OFF switch is turned to "OFF"             
The remote is too far away from the heater       
The remote control receiver is turned "Off"        
One of the two remote control batteries is dead 
See "Starting the Pilot Light"
See "Starting the Pilot Light"
Turn the ON/OFF switch to "ON"
Use  the  remote  closer  to  the  heater
See  the  remote  control  instructions
See  the  remote  control  instructions
Thermostat Does
Not Work
The pilot light has gone out                             
The gas control valve is turned to "PILOT" or "OFF"
The ON/OFF switch is turned to "OFF"             
The thermostat is set too low                          
See "Starting the Pilot Light"
See "Starting the Pilot Light"
Turn the ON/OFF switch to "ON"
See "Thermostat Operation"
Heater Will Not
Distribute Heat
The  heater  is  not  getting  electricity                  
The heater is not up to temperature                 
Check the breaker switch
See "Operating Your Heater"
Pilot Goes Out
Intermittently
The gas supply has been shut off                    
Keep the gas supply turned on
Flames Are Too
Blue
The heater has just been started                     
Improper  air  shutter  adjustment                      
This is normal - see "Starting the Heater
for  the  First  Time"
Adjust Air Shutter - contact your dealer
Flames Are Too
Short (Under 6")
The flame height may be turned too low            
Turn the flame height to "HI" -
See "Adjusting the Flame Height"
Thin Layer of Soot
Covers the Glass
The logs or coals are placed incorrectly            
Improper  air  shutter  adjustment                      
See "Log Set Installation"
Adjust Air Shutter - contact your dealer