Regency Wraps P36-LPG4 Manual Do Utilizador

Página de 44
Regency
®
 P36-4 Gas Log Fireplace
14
FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONS
SIMPSON DURA-VENT DIRECT  FLUE GS SYSTEM and
REGENCY
®
 CO AXIAL FLUE SYSTEM (FLEX)
(LPG & NG)
The diagram below shows examples of horizontal termination arrangements using two 90
o
 elbows (two  45
elbows equal one 90
o
 elbow).
Note: 1) 
maximum 
of 
two 
90
o
 elbows are permitted. 
 
2)  A minimum of 6 ft. (1.8m) vertical from base of unit is required if two 90
o
 elbows are used.
 
3)  Minimum distance between elbows is 2 ft. (0.6m).
 
4)  Determine the permitted range of horizontal termination arrangements by using chart in section "Simpson Dura-vent    
 
 
Flueing." and deducting 3 ft. (0.9m) from the maximum horizontal distance for the second 90
o
 elbow.
Simpson Dura-Vent
4" inner diameter
6-5/8" outer diameter
•   Maintain clearances to combustibles as listed in section "Clearances."
•   Horizontal fl ue must be supported every 3 feet (0.9 meters).
•   Firestops are required at each fl oor level and whenever passing through a wall.
A fl ue guard should be used whenever the 
termination is lower than the specifi ed minimum 
or as per local codes.
If length "B" is increased, length "A" must be 
decreased by a corresponding amount.
INSTALLATION