Ariston E-COMBI 24 30 38 Manual Do Utilizador

Página de 56
14
installation
Connecting the boiler to the system
- Remove the boiler casing as described on page 16
- Remove the caps and connect the valves to the boiler using the 
washers provided
- 4 x fi bre washers for the CH fl ow and return, cold water inlet and hot 
water outlet connections
Installing the Boiler
Please check that you are familiar with the installation requirement 
before commencing work (pages 7 - 13).
The installation accessories described in the following list are included 
in the boiler packaging:
- Hanging 
bracket
-  A paper template (showing the dimensions of the boiler with 5 
mm side clearances)
Connection valves (compression)
- Washers
- Filling 
loop
Installation, Servicing and Operating Instructions
- Flue 
gasket
Method of positioning the boiler on the wall
The paper template can be used to ensure the correct positioning of 
kitchen cabinets etc.
The paper template has to be fi xed to the wall and used to locate the 
position of the hanging bracket and the centre for the fl ue hole.
Drill and plug the wall and secure the hanging bracket using the 
screws provided ensure the hanging bracket is level.  Remove the 
boiler from its packaging and remove the front casing panel.
Place the boiler on the hanging bracket.
N
OTE
: T
HE
 
APPLIANCE
 
MUST
 
NOT
 
BE
 
FITTED
 
ON
 
A
 
COMBUSTIBLE
 
WALL
 
SURFACE
.
Note: Connections viewed from behind boiler
Note: Connections viewed from behind boiler
E-COMBI
E-SYSTEM