Ariston E-COMBI 24 30 38 Manual Do Utilizador

Página de 56
23
installation
Table of fl ue gas exhaust duct lengths
Type
Maximum Extension    Exhaust-air (m)
Diameter of pipe
(mm)
E-COMBI 24
E-SYSTEM 24 
E-COMBI 30
E-SYSTEM 30 
E-COMBI 38
MIN
MAX
MIN
MAX
MIN
MAX
Coaxial System
C13
C33
0,5
12
0,5
12
0,5
6
ø 60/100
C13
C33
0,5
36
0,5
36
0,5
18
ø 80/125
Twin-pipe System
C13
C33
S1 = S2
S1 = S2
S1 = S2
ø 80/80
0,5/0,5
36/36
0,5/0,5
48/48
0,5/0,5
18/18
C53 
1 + S2
1 + S2
1 + S2
ø 80/80
1/0,5
1/83
1/0,5
1/70
1/0,5
1/42
 S1 = Air intake  S2 = Flue gas exhaust
S1 = S2 - Air intake and fl ue gas exhaust equal lengths
S1 + S2 - Air intake and fl ue gas exhaust unequal lengths
Combustion air intake from outside
C13
Flue gas exhaust and air suction 
duct through external wall in 
the same range of pressure
C33
Flue gas exhaust andair suction 
duct from outsidewithroof 
terminalin the same range of 
pressure
C53
Flue gas exhaust leading 
outside and air suction duct 
through external wall not in the 
same range of pressure
Type of air suction/fl ue gas exhaust ducting