 Indirect-Fired Water Heaters – Series 3
 ELECTRICAL  SHOCK  HAZARD
—  For  your  safety,  turn  off  electrical
power  supply  at  service  entrance  panel
before making any electrical connections
to avoid possible electric shock hazard.
Failure to do so can cause severe personal
injury or death.
 Wiring must be N.E.C. Class 1.
If original wiring as supplied with boiler
must be replaced, use only type 10 °C
wire or equivalent.
Boiler must be electrically grounded as
required  by  National  Electrical  Code
ANSI/NFPA 0 – latest edition.
Installation must comply with:
1.  National Electrical Code and any other national,
state, provincial or local codes or regulations.
2.  In Canada, CSA C22.1 Canadian Electrical Code
Part 1, and any local codes.
Line voltage connections
1.  Connect  120 VAC  power  wiring  to  line  voltage
terminal  strip  in  left  compartment  of  electrical
entrance, as shown in Figure 1, item 1.
2.  Provide and install a fused disconnect or service
switch (1 amp. recommended) as required by the
code. (See Figure 1, item 2)
Wiring boiler circulator
1.  The Taco 0011 circulator supplied with the boiler is
wired one of two locations, depending on whether
system is combined space heating/water heating or
dedicated  water-heating  only.  Boiler  circulator  is
shipped loose. Wire Boiler circulator to terminals
(refer to Figure 1):
a.  Combined system: terminals , , and  (installed as
Figure 1, item ).
b.  Dedicated system: terminals , , and ground wire nut
(installed as Figure 1, item ).
Wiring water heater circulator
1.  For combined systems, connect water heater circu-
lator to line voltage terminal strip terminals  and
 and ground wire nut. See Figure 1.
Figure 17 
Line voltage field wiring connections (service switch provided by installer)
Field wiring — 
 Gas boilers only
B3
Gas