Locations and Functions of Parts
CAMERA connector (optical fiber connector)
Used to connect a video camera, using an optical fiber 
cable. All video camera signals, including power supply, 
control, video, and audio, are sent and received over one 
optical fiber cable.
Dust on the connection surface of the optical fiber cable 
may result in transmission errors. When not connected, 
always cover the end of the connector with the supplied 
cap.
Expansion slots
For installation of an optional HKCU1001 SD Encoder 
Unit, HKCU1003 Multi Interface Unit, or HKCU1005 
SDI Output Expansion Unit.
For details on installation, contact a Sony service or sales 
representative.
INTERCOM/TALLY/PGM (intercom/tally/
program audio) connector (D-sub 25-pin)
Used for input and output of intercom, tally, and program 
audio signals. Connect to the intercom/tally/program audio 
connector of the intercom system.
MIC REMOTE (microphone remote) connector 
(D-sub 15-pin)
Using this connector, the video camera’s microphone 
input level may be set by external equipment such as an 
audio mixer, in five level (-60, -50, -40, -30, and -20 dB). 
When shooting, set the volume to a level appropriate for 
the audio conditions.
This connector also supplies a red tally signal and a green 
tally signal.
The microphone input level may also be set using the setup 
menu. For details on the setup menu, contact a Sony 
service or sales representative.
WF REMOTE (waveform monitor remote) 
connector (D-sub 15-pin)
Used to attach to the appropriate connector on a recall-type 
waveform monitor when operating the waveform monitor 
display using an MSU-900 series Master Setup Unit or an 
RCP-700/900 series Remote Control Panel.When using a 
recall-type monitor, preset a display mode on the 
waveform monitor, and then recall the mode externally.
For details on these operations, refer to the Master Setup 
Unit or Remote Control Panel manuals.
TRUNK LINE connector (D-sub 9-pin)
Used to connect to the CCU connector on a video camera 
via an RS-232C interface. Used mainly for communication 
with equipment on the camera side.
Communication with up to two channels is available.
I/O PORT connector (D-sub 15-pin)
Used for remote control using an external control device.
Use of a case wider than 42 mm can cause interference at 
connectors 2, 4, 5. It is recommended that you use a JAE-
made DA-C1-J10.
WF MODE (waveform monitor mode output) 
connectors (4-pin)
Connect to the appropriate connector on a waveform 
monitor when monitoring a signal in sequential mode.
A sequence signal will be output when the SEQ button on 
the RCP-700/900 series Remote Control Panel is pressed, 
allowing simultaneous monitoring of the R, G, and B 
signals in sequential mode. When both the RCP and MSU 
are in use, this connector functions as the output connector 
for RCP control.
For details on these operations, refer to the Master Setup 
Unit or Remote Control Panel manuals.
RCP/CNU connector (8-pin)
Used to connect to an MSU-900 series Master Setup Unit, 
CNU-700 Camera Command Network Unit, or RCP-700/
900 series Remote Control Panel via a CCA-5 Connection 
Cable. Control signals are sent and received via this 
connector. 
When using an RCP-700/900 series unit, power is also 
supplied.
TRUNK A connector (12-pin)
Used to connect to the CCU connector on a video camera 
via an RS-232C or RS-422A interface. Communication 
with up to two channels is available.
MIC1, MIC2 (microphone output 1, 2) connectors 
(XLR 3-pin)
Used to supply the microphone signal sent from the video 
camera.
AC IN (AC power input) connector
Use the specified AC power cord to connect to an AC 
power supply. The AC power cord can be secured to this 
unit, using the plug holder (optional).
HKCU1001 SD Encoder Unit 
(optional)
To reduce the risk of electric shock, fire or injury, do not 
open the cabinet. To adjust the internal settings, refer to 
qualified service personnel.
Note
Note
Note