3.7 
USB Storage Device Data Transfer
3.7.1  Insertion
A USB Storage device or key can be inserted into the controller at either run time or prior to booting. Such a device is 
convenient for transferring setup files to the controller, or for retrieving data files from it. For instance, you can copy an 
entire setup to an Insight controller and avoid having to enter each parameter manually.
When a USB storage key is inserted into the USB port on the Insight controller, the unit’s software acts according to the 
rules found in the following table:
Insert Key After Boot
Insert Key Before Boot
Copy Files From Controller to Key
Copy Files To Key After Controller is Booted
When a USB Storage Device is inserted, an event is logged in the Event Log. When the RISC Software image is updated, 
an event is also recorded in the log. 
3.7.2  Removal
The USB Storage Device can be removed from the controller at either run time or prior to booting. If the device is 
removed, and the controller is not processing a file transfer, no action is taken. If the USB Storage Device is removed 
while the controller is processing a file transfer, the file transfer is interrupted. If a file transfer is in progress when the 
USB removal event occurs, the destination file may be corrupted. The removal of the USB Storage Device is logged in 
the Event Log.
3.8 
PLUS Settings Screen
A settings screen for the PLUS communications protocol is provided for those customers using the protocol.  This screen 
allows the user to manually rest the PLUS communications, abort the current assembly, advance to the next bolt in 
the gang, advance to the next configuration in the auto increment chain, or enable/disable the PLUS communications. 
When the Manual Reset is pressed, the PLUS communication will be reset. If the user wish to abort the assembly 
using PLUS communication, then the user should select the Abort Assembly submenu and then press Enter. During 
the tightening, if there is a failed cycle and the user wish to override the cycle within the gang, then the user should 
select the Gang Advance submenu and then press Enter. During the tightening, if the user wish to override current 
configuration in the auto increment chain then the user should select the Gang Advance submenu and then press 
Enter. If the user wish to enable the PLUS feature, then the user should select the On and then press Enter.
If the user wish to disable the PLUS feature, then the user should select the Off and then press Enter. 