Adapting to different types of gas 
 
The operations described below must be carried out with the appliance not 
connected to the gas supply.
 
The appliance is tested with G20 (2H) natural gas at the pressure of 20 mbar.  
If it is to be used with other types of gas, the burner nozzles have to be changed 
and the primary air flow adjusted. 
To replace the nozzles and adjust the burners, the hob skin has to be removed. 
Proceed as described below. 
 
5.1  Removing the hob skin 
 
 
Remove all the burner 
components in the numerical 
order shown below: 
 
• 
Pull off all the knobs. 
• 
Lift all the burner 
components off the hob. 
 
 
1
 
• 
Remove the hob skin 
fixing screws. 
 
2
 
 
• 
After removing all the 
components described 
above, lift off the hob 
skin.  Release all snap 
connections 
simultaneously (the hob 
is connected to the 
casing underneath in 5 
points). 
 
3
 
During reassembly, after putting the hob skin in position, press down on the 