Instructions for the Installer
 
 
 
26 
5.2  Adjusting for bottled gas 
Undo the screw C and push the air regulator 
D fully down. 
Remove the nozzle E with a 7 mm spanner 
and fit the suitable one, following the 
instructions in the tables referring to the type 
of gas to be used. The nozzle must not be 
tightened with a torque of more than 3 Nm
Regulate the air flow by sliding the 
regulator  D along until the distance 
X” stated in point "0  
Adjusting the primary air flow” is obtained. 
Fix the regulator D by tightening the screw C
 
 
 
Burner
 
Rated 
heat 
capacity 
(kW)
 
 
Bottled gas – G30/G31  30/37 mbar
 
 
 
Nozzle 
diameter 
1/100 mm
By-pass 
mm 
1/100 
Reduced 
heat 
capacity 
(W)
 
Flow 
rate g/h 
G30
 
Flow 
rate g/h 
G31
 
Auxiliary
 
1.05 
48 
30 
400 
76 
75 
Semi rapid
 
1.7 
62 
32 
450 
124 
121 
Rapid
 
80 
50 
1050 
218 
214 
3.0 
Ultra Rapid 
 
 4.2 
100 
63 
1600 
305 
300