Справочник Пользователя для Smeg PX140

Скачать
Страница из 16
 
Instructions for the Installer
 
 
 
27 
5.3  Adjusting for natural gas 
The appliance is tested with G20 (2H) natural gas at the pressure of 20 mbar. To return the 
appliance to the condition required to use this type of gas, proceed as described in 
point “
 
5.2 Adjusting for bottled gas” but select the nozzles and adjust the primary air 
flow for natural gas, as indicated in the table below and in point “
 
5.4  Adjusting the 
primary air flow”. 
 
Burner
 
Rated heat  
Capacity (kW)
Natural gas - G20 20 mbar
 
 
 
Nozzle diameter 
Reduced heat capacity 
1/100 mm
 
(W)
 
Auxiliary
 
1.05 
73 
400 
Semi rapid
 
1.7 
92 
450 
Rapid
 
3.0 
123 
1050 
Ultra Rapid
 
4.2 
150 
1400 
 
5.4  Adjusting the primary air flow 
Refers to the gap “X” in mm. 
 
BURNER
 
G20 
20 mbar
 
G30/G31 
30/37 mbar
 
0.5 
Auxiliary
 
Semi rapid
 
0.5 
 
3.5 
Rapid 
 
Ultra Rapid
 
open
 
 
To identify the burners on your hob, refer to the drawings in point “ 5.8  Hob burner 