Справочник Пользователя для hussman IGFP-R3

Скачать
Страница из 33
Rev. 0608 
15
non-glare glass
Windex
®
 or Glass Plus
®
 are the only solutions recommended 
to be used to clean the non-glare glass. The damage to the 
glass from improper, caustic solutions is irreparable.
In addition to cleaning the glass with the recommended 
product, there are precautions that should be taken when 
working and cleaning the inside of the case.
•   When cleaning the inside of the cases, we 
recommend that the glass be fully opened and 
covered to prevent to prevent solutions from 
splashing onto the glass and ruining the coating on 
the inside.
Plexiglass and acrylic care
Improper cleaning not only accelerates the cleaning cycle 
but also degrades the quality of this surface. Normal daily 
buffing motions can generated static cling attracting dust 
to the surface. Incorrect cleaning agents or cleaning cloths  
can  cause  micro  scratching  of  the  surface,  causing  the 
plastic to haze over time.
cleaning
Hussmann recommends using a clean damp chamois, or a 
paper towel marketed as dust and abrasive free with 
210
®
 
Plastic cleaner and Polish available by calling Sumner 
Labs at 
1-800-542-8656. Hard, rough cloths or paper towels 
will scratch the acrylic and should not be used.
antistatic coatings
The 
210
®
  has  proven  to  be  very  effective  in  not  only 
cleaning  and  polishing  the  Plexiglass  surface,  but  also  
providing antistatic and anti-fog capabilities. This product 
also seals pores and provides a protective coating.
User information (cont'd)
                          
CLEANING PRECAUTIONS
When cleaning:
• Do not use high pressure water hoses
• Do not introduce water faster than waste outlet can drain
• NEVER ON A SELF CONTAINED UNIT WITH AN EVAPORATOR FAN
• NEVER USE A CLEANING OR SANITIZING SOLUTION THAT HAS AN OIL 
   BASE (these will dissolve the butyl sealants) or an AMMONIA BASE 
    (this will corrode the copper componets of the case)
TO PRESERVE THE ATTRACTIVE FINISH:
• DO USE WATER AND A MILD DETERGENT FOR THE EXTERIOR ONLY
• DO NOT USE ABRASIVES OR STEEL WOOL SCOURING PADS  
   (these will mar the finish)
evaporator fans
The evaporator fans are located at the center front of these 
merchandisers directly beneath the display pans. Should 
fans or blades need servicing, always replace fan blades 
with the raised embossed side of the blade TOWARD THE 
MOTOR.
copper coils
The copper coils used in Hussmann merchandisers may 
be repaired in the field. Materials are available from local 
refrigeration wholesalers.
Hussmann recommends using #15 Sil-Fos for repairs.
tips and troubleshooting
Before calling for service, check the following:
1.   Check electrical power supply to the equipment for 
connection.
2.   Check fixture loading. Overstocking case will affect 
its proper operation.
3.   If frost is collecting on fixture and/or product, 
check that no outside doors or windows are 
open -  allowing moisture to enter store. These 
merchandisers were designed for use in stores were 
temperature & humidity does not exceed 75° F and 
55% H.