electronic expansion valve (optional)
A  wide  variety  of  electronic  expansion  valves  and  case 
controllers  can  be  utilized.  Please  refer  to  EEV  and 
controller  manufacturers  information  sheet.  Sensors  for 
electronic expansion valves will be installed on the coil inlet, 
coil outlet, and in the discharge air. (Some supermarkets 
require a 4th sensor in the return air). Case controllers will 
be located in the electrical raceway or under the case. The 
front Self Service Evaporator has an EPR valve installed to 
maintain a constant discharge temperature. It is located in 
the front at the right side of the case under the fan plenum 
near the TX valve.
thermostatic expansion valve location
This device is located on the same side as the refrigeration 
stub. A  Sporlan  balanced  port  expansion  valve  model 
is  furnished  as  standard  equipment,  unless  otherwise 
specified by customer.
expansion valve adjustment
Expansion  valves  must  be  adjusted  to  fully  feed  the 
evaporator.  Before  attempting  any  adjustments,  make 
sure the evaporator is either clear or very lightly covered 
with frost, and that the fixture is within 10°F of its expected 
operating temperature.
Measuring the operating Superheat
1.   Determine the suction pressure with an accurate 
pressure gauge at the evaporator outlet.
.   From a refrigerant pressure temperature chart, 
determine the saturation temperature at the 
observed suction pressure.
3.   Measure the temperature of the suction gas at the 
thermostatic remote bulb location.
electrical
Refrigeration (cont'd)
wiring color code
CASE MUST BE GROUNDED
NOTE:   Refer to label affixed to case to determine the actual 
configuration as checked in the “TYPE INSTALLED” 
boxes.
Electrical Circuit Identification
Standard  lighting  for  all  refrigerated  models  will  be  full 
length  fluorescent  lamps  located  within  the  case  at  the 
top.
The  switch  controlling  the  lights,  the  plug  provided  for 
digital scale, and the thermometer are located at the rear 
of the case mullion.
The receptacle that is provided on the exterior back of these 
models is intended for computerized scales with a five amp 
maximum load, not for large motors or other high wattage 
appliances. It should be wired to a dedicated circuit.
electrical Service Receptacles (when applicable)
The receptacles located on the exterior of the merchandiser 
are intended for scales and lighted displays. They are not 
intended  nor  suitable  for  large  motors  or  other  external 
appliances.
4.   Subtract the saturation temperature obtained in step 
No.  from the temperature measured in step No. 3. 
The difference is superheat.
5.   Set the superheat for 5°F - 7°F. 
evaporator Pressure Regulator
An Evaporator Pressure Regulator is installed in the front 
of the self service section to maintain a constant discharge 
temperature. It is located at the front right side of the case, 
under the fan plenum near the TX Valve.
Service case temperature control
Temperature control in the upper section of the R3 with 
the Service Option is done by means of a thermostat and 
suction  solenoid  valve. This  controls  both  temperature 
and humidity.
t-Stat location
T-STATS are located within the electrical raceway. Refer 
to diagram below.
T
-Stat &
Ballast
(Located in the
same place for
hot and cold)
Rear Storage
T-Stat and
Solenoid inside
Storage Area
Front Coils
controlled by
EPR Valve
under Deck Pan
(Right side)