BEFORE SERVICING
ALWAYS DISCONNECT ELECTRICAL
POWER AT THE MAIN DISCONNECT
WHEN SERVICING OR REPLACING ANY
ELECTRICAL COMPONENT.
This includes (but not limited to) Fans, Heaters
Thermostats, and Lights.
field wiring and Serial Plate amperage
Field Wiring must be sized for component amperes printed 
on the serial plate. Actual ampere draw may be less than 
specified. Field wiring from the refrigeration control panel to 
the merchandisers is required for refrigeration thermostats. 
Most component amperes are listed in the “Case Specs” 
section, but always check the serial plate.
Ballast location
Ballasts are located within the access panel that runs the 
length of the rear of the case.
User information
Stocking
Improper  temperature  and  lighting  will  cause  serious 
product  loss.  Discoloration,  dehydration  and  spoilage 
can be controlled with proper use of the equipment and 
handling of product. Product temperature should always 
be  maintained  at  a  constant  and  proper  temperature. 
This  means  that  from  the  time  the  product  is  received, 
through storage, preparation and display, the temperature 
of the product must be controlled to maximize life of the 
product. Hussmann cases were not designed to “heat up” 
or “cool down” product - but rather to maintain an item’s 
proper temperature for maximum shelf life. To achieve the 
protection required always:
1.   Minimize processing time to avoid damaging 
temperature rise to the product. Product should be 
at proper temperature.
.   Keep the air in and around the case area free 
of foreign gasses and fumes or food will rapidly 
deteriorate.
3.   Maintain the display merchandisers temperature 
controls as outlined in the refrigerator section of this 
manual.
4.   Do not place any product into these refrigerators 
until all controls have been adjusted and they 
are operating at the proper temperature. Allow 
merchandiser to operate a minimum of 6 hours 
before stocking with any product.
5.   When stocking, never allow the product to extend 
beyond the recommended load limit. 
air discharge 
and return air flow must be unobstructed at all 
times to provide proper refrigeration.
6.  Keep the service doors closed (when applicable). 
Refrigeration performance will be seriously affected 
if left open for a prolonged period of time.
7.   Avoid the use of supplemental flood or spot lighting. 
Display light intensity has been designed for 
maximum visibility and product life at the factory. 
The use of higher output fluorescent lamps (H.O. 
and V.H.O.), will shorten the shelf life of the product.
FOR PROMPT SERVICE
When Contacting the Factory regarding problems.
 Be sure to have the Case MODEL and 
SERIAL NUMBER Handy. This Information 
is on a plate located on the case itself.
cleaning glass and Mirrors
Only use a soft cloth and mild glass cleaning for cleaning 
any glass or mirrored components. Be sure to rinse and/or 
dry completely.
never use hot water on cold glass surfaces! it may 
shatter and cause serious injury! Allow glass surfaces 
to warm first.
Replacing fluorescent lamps
Fluorescent  lamps  are  furnished  with  a  shatterproof 
protective coating. The same type of lamp with protective 
coating must be used if replaced.
ENCAPSULITE
SHATTERPROOF COATING - SA 10645
Complies with FDA USDA
& OSHA Regulations
for replacement call:
1-800-395-9229
Turn switch off then on after replacing bulb
NSF
U R
R
electrical (cont'd)