Справочник Пользователя для hussman IGFP-R3

Скачать
Страница из 33
Rev. 0608 
5
10. Use finger to smooth silicone as thin as possible at 
masking tape on inside and outside of rear mullion 
(apply additional silicone if necessary). Remove 
tape applied on line #3.
corner wedges
Corner wedges are attached via front and rear camlocks. 
Use  a  7mm  allen  wrench  to  turn  the  locks.  Do  not  
overtighten! Join the top by using a joint bracket (included 
in joint kit) with 3/8” bolts.
Joint trim
After cases have been leveled and joined, and refrigeration, 
electrical, and wasted piping work completed, install the 
splashguards. Fasten along the top edge, or center, with 
#10 X 3/3” sheet metal screws.
DO NOT SEAL JOINT TRIM TO FLOOR!
installation (cont'd)
Scale Stand installation instructions
1.- Set Scale Stand to desire location
2.- Drill holes and screw in place
(with screws provided – Hex Tek S/S 
10-16 X ½”)
Note: Use hole pattern