Техническая Спецификация для Infineon Technologies KITXMC2GOXMC1100V1TOBO1

Скачать
Страница из 57
XMC1100
XMC1000 Family
Electrical Parameter
 
Data Sheet
45
V1.4, 2014-05
 
3.3.7
Peripheral Timings 
 
Note: These parameters are not subject to production test, but verified by design and/or
characterization.
3.3.7.1
Synchronous Serial Interface (USIC SSC) Timing 
The following parameters are applicable for a USIC channel operated in SSC mode.
Note: Operating Conditions apply.
Table 23
USIC SSC Master Mode Timing
Parameter
Symbol
Values
Unit
Note / 
Test Condition
Min.
Typ. Max.
Slave select output SELO 
active to first SCLKOUT 
transmit edge
t
1
 CC
80
ns
Slave select output SELO 
inactive after last 
SCLKOUT receive edge
t
2
 CC
0
ns
Data output DOUT[3:0] 
valid time
t
3
 CC
-10
10
ns
Receive data input 
DX0/DX[5:3] setup time to 
SCLKOUT receive edge
t
4
 SR
80
ns
Data input DX0/DX[5:3] 
hold time from SCLKOUT 
receive edge
t
5
 SR
0
ns
Table 24
USIC SSC Slave Mode Timing
Parameter
Symbol
Values
Unit
Note / 
Test Condition
Min.
Typ. Max.
Select input DX2 setup to 
first clock input DX1 transmit 
edge
1)
t
10
 SR 10
ns
Select input DX2 hold after 
last clock input DX1 receive 
edge
t
11
 SR 10
ns
Subject to Agreement on the Use of Product Information