Справочник Пользователя для Omni Group GREEN SMART 864

Скачать
Страница из 72
 
Installation
  
(for qualified installers only)
 
37 
© Travis Industries 
4090507 
100-01217_000 
Mantel Requirements 
 
Combustible Mantels 
•  Use the table below to determine the maximum mantel depth allowed.  The mantel depth (measured from the 
face of the fireplace) must fall in the shaded portion of the table. 
•  Any material that protrudes more than 3/4” (19mm) from the non-combustible facing is considered a mantel 
and must meet the mantel requirements. 
36-3/4"
933mm
a
b
Maximum Mantel Depth (b)
Mantel 
Height 
Above 
Face (a)
0”
(25mm) 1"
 (51mm) 2"
 (203mm) 8"
 (178mm) 7"
 (152mm) 6"
 (127mm) 5"
 (102mm) 4"
 (76mm) 3"
(229mm) 9"
0”
(254mm) 10"
(279mm) 11"
(305mm) 12"
(330mm) 13"
(356mm) 14"
(381mm) 15"
(406mm) 16"
(432mm) 17"
(457mm) 18+"
Base of the Fireplace
Combustible mantel columns (legs) that protrude 
more than 3/4" (0.75mm) from the glass frame 
must meet the sidewall clearance. If they 
protrude 3/4" (0.75mm) or less, they must meet 
the facing clearance 2-1/4" (57mm) from the 
glass frame.  
Non-combustible mantel columns do not have a 
minimum clearance.
Combustible Mantel
1" (25mm)
2" (51mm)
8" (203mm)
7" (178mm)
6" (152mm)
5" (127mm)
4" (102mm)
 3" (76mm)
9" (229mm)
10" (254mm)
11" (279mm)
12" (305mm)
 
Examples: 
- If you wish to have an 8” (203mm) deep mantel, it must be at least 6-3/4” (171mm) above the fireplace face (44-3/4”, 1137mm above the base). 
- If you wish to have a mantel 8” (203mm) above the fireplace face, it must be no deeper than 9” (229mm). 
Non-Combustible Mantels 
Non-combustible mantels must meet the clearances listed for combustible mantels.  However, if you do wish to 
reduce the clearances by using a non-combustible mantel, the following requirements must be met: 
• Non-combustible 
mantel 
and facing must extend 
from the top of the 
appliance to the top 
surface of the mantel. 
• A 
non-combustible 
header must be used 
(metal stud). 
SIDE OF FIREPLACE
Drywall
Non-Combustible Mantel
Non-Combustible Framing (metal studs)
must be used for the header.
Non-Combustible Facing