Finalizing the Installation
  
(for qualified installers only)
 
39 
© Travis Industries 
4090507 
100-01217_000 
5.  Install the logs (see page 42). 
6.  Replace the glass. 
7.  Start the heater.   
8.  Leak test all gas joints.   
9.  Check the air shutter following the directions below. 
Air Shutter Adjustment  
Let the heater burn for fifteen minutes (make sure the logs and glass are in place).  The flames should be 
yellow with no sooting.  Adjust the air shutter, if necessary, to achieve the correct looking flame. 
Correct
Flames should be blue at the 
base, yellow-orange on the top.
If the flames are too tall or sooty on the 
ends, open the air shutter.
Not Enough Air
If the flames are all blue and 
short, close the air shutter.
Too Much Air
Air Shutter Adjustment 
Outer Burner Air Shutter Control
(RED)
Left = Less Air
Right = More Air
Center Burner Air Shutter Control
(GOLD)
Left = Less Air
Right = More Air
NOTE
: you may wish to use pliers to adjust the front 
air shutter.  Typically, the front air shutter is fully closed 
(left) on NG, fully open (right) on LP
10.  Turn the flame adjust knob to its highest position - the flames should not contact the top of the firebox.  Check the flame 
on low position.  The flames should burn off of each burner hole.  If the heater does not work correctly, contact your Travis 
dealer for a remedy. 
11.  Give this manual to the home owner for future reference and fully explain operation of this heater.  For comprehensive 
operating and maintenance instructions, refer to the Owner's Manual (part # 100-01219). 
ACID WASH WARNING:  Before installing the faceplate, make sure any masonry that has been treated with acid wash has 
been properly neutralized (this is used primarily with brick faces).  Acid wash (muriatic acid) is used to remove excess mortar.  
If not properly neutralized with an ammonia solution, the plated face may develop a permanent tarnish when the acid 
evaporates over time.  Contact your dealer if uncertain your facing has been properly neutralized.