Electrical requirements
You can find the identification plate with the electrical 
specifications on the underside of the appliance. The 
junction box must be located within 3 feet of the 
cooktop connection. It should be easily accessible for 
service purposes.
Power Supply
Models VI 414 610, VI 424 610
20 Amp circuit breaker
240 Volt, 3 Wire, 60 Hz
208 Volt, 3 Wire, 60 Hz
All with 39" (1 m) flexible conduit (included)
Prepare Installation Space
The kitchen unit must be heat-resistant to at least 
200° F (90°C). The stability of the unit must be 
maintained after producing the cut-out.
Produce the cut-out in the countertop for one or more 
Vario appliances as shown in the installation sketch. 
The angle between the cut surface and the countertop 
must be 90°.
The cut edges at the sides must be flat to ensure a 
good fit of the retaining springs on the appliance. In 
laminated worktops, it may be necessary to fit strips at 
the sides of the cut-out.
Remove shavings after cutting. Seal cut surfaces for 
resistance to heat and so they are watertight.
Pay attention to a minimum gap of 3/8“ (10 mm) from 
the underside of the appliance to kitchen units.
The worktop must be reinforced if it is less than 
20 mm (¾”) thick when installed overlapping or less 
than 30  mm (1 
3
/
16
”) when installed flush. Otherwise, it 
is not stable enough. Reinforcement material used 
must be resistant to heat and moisture.
Notes
The worktop where the appliance is installed 
should be able to support a weight of 
approximately 60 kg. 
The appliance levelling should only be checked 
after it is installed in the gap for the built-in unit.
Cutting out countertop
´$SSUR[LPDWH
Å-´%R[
&RQGXLWDSSUR[IHHW
[
ƒ
¡
PP
PLQ
PLQ


PLQ



“



“


  PP



“

“


PLQ