 Reference, Installation, and Operations Manual
Section 6: Meter operation
3-9000-743 Rev S
June 2013
Energy rate and totals
 203
Read delta volume registers (either the FLOAT registers or the LONG register pairs) in a single 
Modbus read. If the delta volume registers are read as LONG register pairs, calculate each delta 
volume as follows:
Equation 6-20  Triggered Delta volume
where
Repeat "P
ERIODIC
 L
OOP
"
6.1.12
Energy rate and totals
The Daniel Mark III Ultrasonic Gas Flow Meter meter calculates the energy rate and energy totals 
(forward and reverse). These calculations requires that the flow-condition pressure and 
temperature are available (either fixed or optional analog inputs, 
), the gas 
property data (composition and heating value) are available (either fixed or optionally read from 
a GC, 
), and the AGA8 calculations are performed (internally by the meter or 
externally with the results written to the meter, 
).
The energy rate is calculated as shown in 
.
Equation 6-21  Energy rate
where
The sign of the energy rate indicates the flow direction: a positive value indicates flow in the 
forward direction, a negative value indicates flow in the reverse direction.
=
triggered delta volume (forward or reverse, flow-condition or 
base-condition) (m
3
 or ft
3
) (
TrigDeltaPosVolFlow, 
TrigDeltaNegVolFlow, TrigDeltaPosVolBase, 
TrigDeltaNegVolBase)
=
triggered delta volume overflow integer value (forward or 
reverse, flow-condition or base-condition) (1e
9
m
3
 or 1e
9
ft
3
)
=
triggered delta volume lower integer value (forward or 
reverse, flow-condition or base-condition) (m
3
 or ft
3
)
=
energy rate (MJ/h) (
EnergyRate)
=
base-condition volumetric flow rate (m
3
/h) (
QBase)
=
“in-use” heating value (kJ/dm
3
) (
HeatingValueInUse)
DeltaVolume
Overflow
1e9
×
(
Lower
+
=
DeltaVolume
Overflow
Lower
Q
E
Q
Base
HV
×
1MJ
1000kJ
------------------
1000dm
3
1m
3
----------------------
×
×
=
Q
E
Q
Base
HV