ICP-CC488 | Installation Guide | 19.0  
Partitioning 
EN | 84 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
19.0  Partitioning 
The ICP-CC488 Control Panel includes the 
partitioning feature, which can effectively transform 
your single control panel into two separate areas. 
Normally, arming and disarming the system turns the 
entire system on or off. When the ICP-CC488 
Control Panel is partitioned, you can arm or disarm 
an individual area without affecting the other area. 
Partitioning is extremely useful when you want to 
secure sheds, dual occupancy dwellings, accessory 
dwellings, shops, and offices.
 
Only the CP5 Area Addressable (CP500A) codepad 
and the CP5 Master Partitioned (CP500P) codepad 
can be used in partitioned systems. 
19.1  CP500 Master Partitioned LED 
Codepad 
Figure 17:  ICP-CP500PW Master Partitioned 
Codepad 
 
 
This codepad is only used on a partitioned ICP-
CC488 Control Panel. The Master Partitioned LED 
codepad allows a user to operate both areas 
individually from the same codepad, without the 
need to operate individual areas from separate 
codepads. 
The codepad is the communications interface 
between you and the alarm system. The codepad 
allows you to issue commands and offers visual and 
audible indications to guide you through general 
operation. 
The codepad incorporates a number of indicators: 
eight zone indicators show the condition of each 
zone, eight area indicators show the area status,  and 
four other indicators show general status. These 
indicators are described in detail in Section  ICP-
CP500PW Master Partitioned LED Codepad
 on page 12. 
19.2  Using Codepads in a Partitioned 
System 
19.2.1 
Operating with a CP5 Area Addressable 
LED Codepad 
The display and operations of a CP5 Area 
Addressable (CP500A) codepad in a partitioned 
system are exactly the same as the CP5 Eight Zone 
LED codepad, except that the commands issued 
from the codepad affect only the area to which the 
codepad is allocated. Refer to Section 3.0 System 
Operations
 on page 14 for more information. 
Example 
If the codepad is allocated to Area 2, only User 
Codes that are allocated to Area 2 can operate the 
codepad. If User Codes have access only to Area 1, 
entering the code at the Area 2 codepad does not 
work.   
If you want to determine the area to which the 
codepad you are operating is allocated, hold down 
[8]. If Zone 1 lights, the codepad is allocated to Area 
1. If Zone 2 lights, the codepad is allocated to Area 2. 
Refer to Section 5.4 Hold-Down Functions on page 32 
for more information. 
19.2.2 
Operating with a CP5 Master 
Partitioned Codepad 
Operations using a CP5 Master Partitioned (CP500P) 
codepad in a partitioned system are the same as the 
CP5 Area Addressable codepad with one exception. 
All operations are related only to the lit Area 
Display. If the Area Display 2 is lit, the codepad 
displays information only for Area 2 (that is, all 
operations effect only Area 2). Refer to Section 3.0 
System Operations
 on page 14 for more information. 
To move from one area to the next: 
1.  Press [AWAY]. 
The next Area Display indicator lights (for 
example, if Area Display 1 is lit, pressing 
[AWAY] lights Area Display 2.  
2.  Press [AWAY] to toggle the display back to other 
Area Display indicator.  
In the example, pressing [AWAY] again lights 
Area Display 1. 
19.3 Programming 
Locations 500 and 501 apply only to a partitioned 
ICP-CC488 Control Panel.  
These locations have up to four options. You can 
select any combination of these options by 
programming a single value. Calculate this value by 
adding the option bit numbers together. Refer to 
Section 7.3 Programming Option Bits on page 36 for 
more information.