Lucent Technologies Release 7 用户手册

下载
页码 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-501
DIG-LINE (Digital Line) 
9
5. Audits
As part of periodic maintenance, the hardware status audit test queries 
programmable terminals to determine which levels and/or options are 
being used. If the reported values are not equal to the administered 
values, the system will initiate a terminal download action. This audit does 
NOT check the parameters used for softkeys.
6. Activation of TTI
A terminal is downloaded automatically when it is activated using the 
Terminal Translation Initialization feature. Therefore, no special user 
actions are required for TTI.
NOTE:
Plugging the station cord into a terminal does not automatically 
cause the terminal to be downloaded. If this terminal has factory 
defaults or if the terminal has been previously downloaded with 
parameters different than those desired, use one of the demand 
download actions described below to download the terminal.
Demand Download Actions
1. Busyout/Release Command
A maintenance demand busyout/release request for a station will cause 
the terminal to be downloaded regardless of its previous download status.
2. Feature Access Code
A Refresh Terminal Parameters Feature Access Code can be used to 
request a terminal download action. When this code is followed by a "#", 
the programmable parameters for the current terminal are downloaded 
when the terminal goes on hook. When this code is followed by an 
extension, the programmable parameters for the specified station are 
downloaded.
This Refresh Terminal Parameters Feature Access Code is assigned on 
the second page of the "feature-access-codes" screen.
A confirmation is returned if the download request is accepted. A busy 
tone is returned if the request is made from a different station when the 
target station is off-hook.
The first three green call appearance LEDs on the 84xx 603x terminal will 
be turned on for three seconds if the station was successfully downloaded 
as a result of an entry of a Refresh Terminal Parameters Facility Access 
Code. This is not true for the 302B1 terminal.
There is no visible display on a station for the other background or 
demand download actions. As described below, the "status station" and 
"status attendant" screens can be used to check the download status of a 
specified terminal.