Lucent Technologies Release 7 用户手册

下载
页码 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-502
DIG-LINE (Digital Line) 
9
Status of Parameter Downloads
The "status station" and "status attendant" screens display the current download 
status of individual 84xx, 603, and 301B1 terminals in the Download Status field. 
The possible download states are:
Possible reasons for terminal being not downloaded include:
— Terminal is off-hook.
— Terminal detected a bad checksum.
— Terminal detected a bad or missing EEPROM (refer to hardware error log).
— Terminal is busy programming data from a previous PROGRAM message.
— Terminal is in the Programming Disabled state.
— Terminal is in the Local Program Options Mode.
— Terminal is disconnected or out of service (use status station command).
Error Log Entries and Test to Clear Values
Status
Explanation
Complete
Terminal successfully downloaded sometime in the past.
Pending
System waiting to download the terminal. This may require the 
execution of a background periodic test which could take more 
than an hour. A demand download as described above may also be 
used to initiate an immediate download.
Not Applicable
 Not a programmable terminal.
Table 9-205.
Digital Line Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port 
UUCSSpp sh r 1
1 (a)
40987
None
WARNING
OFF
1 (b)
1 to 20
None
WARNING
OFF
18 (c)
0
busyout port 
UUCSSpp
WARNING
OFF
rel port 
UUCSSpp
130 (d)
None
WARNING
ON
test port 
UUCSSpp sh
257 (e)
40971
None
513
0
Station (Digital) 
Audits Test (#17)
WARNING(
o)
OFF
test port 
UUCSSpp sh r 6
767 (f)
40964
None
WARNING
OFF
769 (g)
40963 
40988
None
WARNING
OFF
Continued on next page