  Chapter 7 Application Programming 
DMC-2X00  
TW 1000 
Set the time out to 1000 ms 
PA 10000 
Position Absolute command 
BGA Begin 
motion 
MCA 
Motion Complete trip point 
EN 
End main program 
#MCTIME 
Motion Complete Subroutine 
MG “A fell short” 
Send out a message 
EN End 
subroutine 
This simple program will issue the message “A fell short” if the A axis does not reach the commanded 
position within 1 second of the end of the profiled move. 
Example - Command Error 
Instruction Interpretation 
#BEGIN 
Begin main program 
IN "ENTER SPEED", speed 
Prompt for speed 
JG speed;BGA 
Begin motion 
JP #BEGIN 
Repeat 
EN 
End main program 
#CMDERR Command 
error 
utility 
JP#DONE,_ED<>2 
Check if error on line 2 
JP#DONE,_TC<>6 
Check if out of range 
MG "SPEED TOO HIGH" 
Send message 
MG "TRY AGAIN" 
Send message 
ZS1 Adjust 
stack 
JP #BEGIN 
Return to main program 
#DONE 
End program if other error 
ZS0 
Zero stack 
EN End 
program 
The above program prompts the operator to enter a jog speed.  If the operator enters a number out of 
range (greater than 8 million), the #CMDERR routine will be executed prompting the operator to enter 
a new number. 
In multitasking applications, there is an alternate method for handling command errors from different 
threads.  Using the XQ command along with the special operands described below allows the 
controller to either skip or retry invalid commands. 
 
OPERAND FUNCTION 
_ED1 
Returns the number of the thread that generated an error 
_ED2 
Retry failed command (operand contains the location of the failed command) 
_ED3 
Skip failed command (operand contains the location of the command after the failed 
command) 
 
The operands are used with the XQ command in the following format: 
 
XQ _ED2 (or _ED3),_ED1,1