Cisco Systems WS-X6608-T1 用户手册

下载
页码 128
3-2
Ci sco Catalyst  4900M Swit ch I nst allati on Guide
78-18350-02
Chapte r 3      Inst allin g t he Swi tch
  Rack-Mount ing the Swi tch
Rack-Mounting the Switch
A rack-moun t kit (69-1821-03) is  included in the accessory kit for mo unting the switch in a standard 
1 9-inch (48.3 cm) four-po st eq uipment rack where the depth of the rack (the distance measured b etween 
th e front and the rear po sts) does not ex ceed 3 2.5 in ches (8 2.5 cm). This rack-mount kit is not suitable 
for racks  with  obstruction s (such as a p ower  strip) th at  cou ld impair  acces s to  the  switch, four-pos t rack 
enclosures  that  exceed  32 .5 inches (82 .5  cm) in depth, o r fo r two-post equipment racks. 
An op tional rack-mou nting k it (C49 00M-BKTS-KIT=) is  available for installing the chassis in  two-post 
telco racks  and  in  fo ur-post  eq uipment racks  that  exceed  32 .5 inches (82 .5 cm) in depth. 
Caution
Befo re installing the chas sis in a rack , read th
to  become familiar with  the proper site and env ironmental con ditions. Failure to read and follow these 
g uidelines  cou ld lead  to an unsu cces sful in stallation and  possible damage  to the system and compon ents.
Caution
This unit is meant to be rack-mo unted, and  is not intended to b ear mo re than its own  weight. Do n ot stack 
mo re th an two  on  a tab le top, the added weight may  damage the bottom chas sis.
Rack-Mounting Guidelines
Befo re rack-moun tin g the switch, en sure the followin g:
  •
The equipment rack is th e proper size.
  –
The width of the rack , between  th e two fron t mou nting strip s o r rails, mu st b e 17.75 inches 
(45.09 cm).
  –
The depth o f th e rack , between the front and  rear mounting  strip s, must b e at least 19.25 inches 
(48.9 cm) but not more than  3 2.5  in ches (8 2.5 cm).
Note
If your four-pos t rack enclo sure exceed s 3 2.5  inches (82 .5 cm) in depth, or you  are 
installing the chassis in  a  two-post equip ment  rack ,  you mu st order and u se  the  optional 
rack-mou nt kit (C4900 M-BKTS-KIT=).
Warning
To prevent bodily injury when mounting or servi cing this unit in a rack, you must take special 
precautions to ensure that the system remains stable. The followi ng guidelines are provided to 
ensure your saf ety:
  •
This unit should be mounted at the bottom of the rack if it is the only unit in  the rack.
  •
When mounting this unit in  a partially  filled rack, load the r ack from the bottom to the top with the heavies t 
component at the bottom of the rack.
  •
If  the rack is provided with stabilizing devices, install the  stabilizers  before mounting or servicing the unit in 
the rack. 
Statement 1006