DS7400XiV4-EXP | User Guide | 6.0   Day to Day Operations 
EN | 15 
 
 
Bosch Security Systems | 6/05 | 4998154961B 
 
6.2.4 Automatic 
Arming 
You can program each area to arm automatically once per day. You cannot program automatic arming from an 
RF (wireless) keypad. Programming automatic arming in Master Keypad mode affects all areas you have access to.  
If you program automatic arming in single area mode or from a single area keypad, it affects only the area you are 
working in. 
Do this procedure at a text keypad because no visual clues are provided from an LED keypad. 
 
Table 12: Automatic Arming 
 
 
 
 
Setting the Automatic Arming Time 
Notes 
[Master PIN][#][0] 
You can only set the Automatic Arming Time in Master Programming Mode. 
[1] 
To enter Automatic Arming Setup programming. 
Enter the area number.  
Press [#] to exit. 
•  If programming from a Master Keypad that is not in Single Partition Mode, you are 
prompted to enter the area to program. 
•  You are allowed to program only the areas to which you are assigned. 
•  If programming from a standard keypad or from a Master Keypad in Single 
Partition Mode, skip this step. 
Enter a time for each day in  
24-hour clock format 
•  Programming starts with Sunday. The keypad displays “Sunday –nn : nn” 
•  Enter the time in 24-hour clock format and press the [#] key. If you make a 
mistake, press the [#] key twice to move back to your last entry. 
•  Time examples:  
12 midnight = 2400# 
12 noon = 1200# 
 
12:01 am = 0001# 
12:01 pm = 1201# 
 
1:00 am = 0100# 
1:00 pm = 1300# 
 
Disabled = 0000# 
 
 
6.2.5 
Delaying Automatic Arming 
When automatic arming is set, a pre-arming period begins 15 minutes before the system arms automatically to 
inform occupants that the system is about to arm. The keypad sounders, and any outputs programmed to follow 
the keypad sounders, pulse five times every minute. During the last five minutes before arming, these sounders are 
on steady. Once per minute the keypad (text keypad only) displays “Arm in nn min./PIN  OFF - extend.”  
To delay automatic arming during the pre-arming period, use the appropriate command sequence from the table. 
To extend the automatic arming time at any time, use the delayed arming feature.  
 
 
 
An RF3341 keypad gives no indication of the pre-arming period and cannot be used to delay automatic 
arming. 
 
Table 13: Delaying Automatic Arming 
 
 
 
 
Equipment  
Command Sequence 
What Happens 
What To Do 
Text Keypad LED 
Keypad 
[PIN][Off] 
The arming time is extended to 30 minutes from 
the time you entered the command sequence. 
A new pre-arming period begins 15 minutes 
prior to the new automatic arming time. 
Exit before the new 
automatic arming time. 
RF3341, 
RF3332/RF3322E, 
RF3334/RF3334E 
Not applicable 
Note: The keypad volume setting also applies to the Auto Arm tone.