6.2.3 Zone 
Bypass 
There might be occasions when you need to temporarily bypass one or more zones before arming the system. 
Bypass commands only work when the control panel is disarmed. For example, an open window can cause the 
text keypad to display “Not Ready” followed by the zone number. The LED keypad might have one of its zone 
LEDs on steady.  
You must be in Single Partition Mode to bypass from a Master keypad. Bypassing without arming is not allowed 
from an RF (wireless) keypad. If more than one zone requires bypassing, enter the additional zone numbers. 
 
 
 
Refer to Section 6.2.2 Force Arming on page 13 for another method to bypass zones. 
 
Table 11: Zone Bypass 
 
 
 
 
Type of 
Bypassing  
Command Sequence 
What Happens 
What To Do 
Bypass Faulted 
Zones 
[PIN][Bypass][XXX] 
[XXX][XXX] * 
The green Status LED flashes if no other 
zones are faulted. 
If desired, arm the control panel 
after bypassing. 
Read Bypassed 
Zones 
[PIN][Bypass]  
•  “Bypass” is displayed on a text keypad 
followed by the zone number(s) of any 
bypassed zones. 
•  All zones normally armed by the arming 
command sequence are armed except 
for faulted zones. 
If desired, arm the control panel 
after bypassing. 
Clear Individual 
Bypassed 
Zone(s) 
[PIN][Bypass][XXX] * 
The specified individual zone bypass is 
cleared. 
If desired, arm the control panel 
after bypassing. 
Clear All 
Bypasses 
[PIN][Bypass][*] 
All bypasses are cleared. 
If desired, arm the control panel 
after bypassing. 
* [XXX] is a 3-digit zone 
number 
You must enter the zone number as a three-digit number. Example: 001, 062, or 125. 
Note: All bypasses are cleared when the system is disarmed, except for 24-hour or Day-Monitor 