Bosch Appliances Home Security System DS7400XIV4-EXP 用户手册

下载
页码 40
DS7400XiV4-EXP | User Guide | 6.0   Day to Day Operations 
EN | 13 
 
 
Bosch Security Systems | 6/05 | 4998154961B 
 
6.2 Optional 
Operations 
6.2.1 Quick 
Arming 
Quick arming allows you to enter some arming commands without first entering a PIN. If quick arming is 
not 
used, you must enter a PIN at the beginning of all arming command sequences. 
 
 
 
Quick arming is not available from a Master keypad or from RF (wireless) keypads. 
 
The following shortcuts are allowed when the system is programmed for quick arming: 
 
Table 9:  Quick Arming 
 
 
 
 
Type of Arming 
Quick Arming Command Sequence 
Normal Arming 
[#][On] 
Perimeter Instant Arming – no entry delay 
[#][No Entry][Perimeter Only] 
Perimeter Arming – entry/exit delay in effect 
[#][Perimeter Only] 
Maximum Security Arming 
[#][No Entry][On] 
 
6.2.2 Force 
Arming 
When one or more zones are faulted (for example, if a window or door is open), the system can be force armed (if 
programmed) by bypassing the faulted zones. When a text keypad displays “Not Ready” and the zone LED(s) on 
an LED keypad for the faulted zone(s) are lit, force arming is required to arm the system. Although an RF3341 
keypad does not indicate a faulted state on the system, you can force arm the system from an RF3341 keypad. 
You can also force arm an area using a master keypad in Single Partition Mode. 
Force Arming during an AC power failure:  Regular arming of the control panel is not permitted during an 
AC power failure. The requirement to force arm serves as a warning that the control panel is operating under 
backup battery. 
 
 
Bypassing or force arming removes some of your building’s protection because it excludes the faulted 
zones from arming. Therefore, an intrusion might not be detected or the detection might be delayed. 
Always attempt to correct any zone problems (close doors and windows, etc.) before using these 
features. If you cannot correct the problem, contact your installing company. 
 
Table 10: Force Arming 
 
 
 
 
Equipment  
Command Sequence 
What Happens 
What To Do 
Text Keypad LED 
Keypad 
Enter any Arming 
Command Sequence. 
Enter [Bypass] during the 
five-second beep. 
•  The red Armed LED flashes during the 
exit-delay period. 
•  All zones normally armed by the 
Arming Command Sequence are 
armed except for the faulted zones. 
If leaving, exit during the exit-
delay period.  
RF3341 Keypad 
Any Arming Command 
Sequence  [9] 
•  The LED flashes indicating a signal 
was sent to your security system. 
•  All zones normally armed by the 
Arming Command Sequence are 
armed except for the faulted zones. 
If leaving, exit during the exit-
delay period.  
RF3332/RF3332E, 
RF3334/RF3334E 
Not applicable 
* Text Keypad only