3-287
The following table shows the S102 parameters.
Example
ATS102? <enter>
030
OK
ATS102=100 <enter>
OK
ATS102? <enter>
100
OK
(This means if there is data for transmission to the terminal, the G24 drops the Wakeup Out line, 
waits 100 ms. and then sends data to the terminal.)
S100, Set Minimum Time for Terminal to Fall into Sleep Mode
ATS100 is a terminal minimum time limit for entering sleep mode.
In order to limit the number of interrupts on the DTE side and reduce data sending delay time on 
our side, G24 sends wakeup-out pulse when the interval between one burst of sent/received data 
to the other is bigger than specified in ATS100.
Command Type
Syntax
Response/Action
Remarks
Set
ATS102 = <value>
OK
The Set command sets the delay before 
sending data to the terminal, and 
defines a period between sending the 
wakeup signal and sending data to the 
terminal.
Read
ATS102? <value>
OK
The Read command returns the current 
value.
Table 3-190: S102 Parameters
<Parameter>
Description
<value>
0 <= value <= 255
The default value is 30 ms.