Motorola G24 Benutzerhandbuch
Modem Configuration and Profile
3-288
AT Commands Reference Manual
December 31, 2007
Example
ats100?
001
OK
ats100=0
OK
ats100?
000
OK
+MSCTS, Enable/Disable CTS During Wakeup Period
This command defines the behavior of the CTS line when the G24 is in normal mode (not Sleep
mode).
mode).
The command configures the G24 CTS line behavior always to follow the flow control
requirements, or to follow it only if the terminal initiated a serial transmission session. This saves
the terminal from following the CTS interrupt every time the G24 exits Sleep mode for internal
G24 reasons (non-terminal communication related reasons).
requirements, or to follow it only if the terminal initiated a serial transmission session. This saves
the terminal from following the CTS interrupt every time the G24 exits Sleep mode for internal
G24 reasons (non-terminal communication related reasons).
Table 3-191: Command parameters
<Parameter>
Description
Remarks
<delta>
Time interval between one burst of sent/received
data to the other before the terminal enters sleep
mode.
0 : Wakeup out feature isn't active. (default when
+S100 set command is never used)
1 - 255: Time in seconds.
data to the other before the terminal enters sleep
mode.
0 : Wakeup out feature isn't active. (default when
+S100 set command is never used)
1 - 255: Time in seconds.
This value is saved on power
down.
down.
Command
Type
Syntax
Response/Action
Remarks
Set
AT+MSCTS=<control>
OK
The Set command tells the G24
whether to activate the CTS when the
unit is awakening.
whether to activate the CTS when the
unit is awakening.
Read
AT+MSCTS?
+MSCTS: <current
control>
OK
The Read command returns the current
control value.
control value.
Test
AT+MSCTS=?
+MSCTS: (list of
supported <control>)
OK
The Test command returns the possible
control values.
control values.