Monessen Hearth EYF18 Benutzerhandbuch

Seite von 32
65D1009
14
EYF Series Unvented Gas Log Set
CONNECTING OPTIONAL REMOTE RE-
CEIVER
FOLLOW INSTRUCTIONS SUPPLIED WITH 
THE REMOTE
1.  Connect  the  wires  to  the  two  .5"  male  connectors 
located  on  the  left  side  of  the  valve  when  facing  the 
unit. Page 19, Figure 16. Do not let wire touch grate or 
burner.
.  Stick velcro pads with self-adhesive backing to the right 
side of remote receiver and to the left side of the unit. 
Figure 17
3.  Attach remote receiver with velcro pads. Control switch 
must face forward.
NOTE:  Heat  reduces  battery  life.  You  can  protect  the 
receiver and extend battery life by mounting the receiver 
in a wall or other location outside the fireplace. 
ELECTRICAL WIRING - MILLIVOLT
CHECkING SYSTEM OPERATION
The  millivolt  system  and  individual  components  may  be 
checked with a millivolt meter having a 1-1000 mV range. 
Conduct each check shown in chart by connecting meter 
test leads to terminals as indicated.
A.  Complete Millivolt System Check
  (“A” Reading - Thermostat contacts CLOSED - Control 
knob “ON” - Main burner should turn ON)
1.  If  reading  is  more  than  175  millivolts  and  the  au-
tomatic  valve  still  does  not  come  on,  replace  the 
control. 
.  If  the  closed  circuit  reading  (“A”  reading)  is  less 
than 175 millivolts, determine cause for low read-
ing, proceed to Section B.
B.  Thermopile Output Reading Check
  (“B” Reading - thermostat contacts OPEN - Main burn-
er OFF
1.  Check gas pressure to the unit. If gas pressure is 
within minimum and maximum on data plate, then 
check  pilot  voltage,  500  millivolts  minimum.  If  the 
minimum millivolt reading is not obtainable, replace 
pilot.
 
 
 
Connect 
Switch or 
Meter
  Check 
 
Meter Leads 
Thermostat 
Reading
 
Test 
To Test 
To Terminals 
Contacts 
Should Be
 
Complete 
 & 3 
Closed 
Minimum 175 
 
 
System
 
Thermopile 
1 &  
Open 
Minimum 500
 
 
Output
LO
HI
OFF
SK
YT
ECH
OFF
ON
RE
MO
TE
FP2540
install remote receiver
Remote 
Receiver
Velcro 
Pads
FP540
Figure 17 - 
Install Remote Receiver