Monessen Hearth EYF18 Benutzerhandbuch

Seite von 32
7
65D1009
EYF Series Unvented Gas Log Set
FIREPLACE and HEARTH DIMENSIONS
W
ARNING
This  appliance  has  been  specifically  tested  and  design  certified  for 
installation  only  in  a  solid-fuel  burning  fireplace  including  factory-built 
UL127  fireplaces  and  masonry  fireplaces,  or  in  a  listed  ventless  firebox 
(see below).
Exception:
 DO NOT install this appliance in a factory-built fireplace that 
includes instructions stating that it has not been tested or should not be 
used with unvented gas logs. 
Use manufacturer's installation and clearance requirements 
as defined in their manual.
The  EYF  Series  unvented  room  heater  is  approved  for 
installation into the following unvented fireplaces:
GCUF(32,36,42) and VFR(32,36,42) Series Fireboxes
The  EYF  Series  unvented  room  heater  may  also  be  in-
stalled  into  a  Ventless  Firebox  Enclosure  for  Gas  Fired 
Decorative  Type  Unvented  Room  Heaters  per  ANSI 
Z1.91b.004, as long as firebox hearth dimensions meet 
the minimum hearth dimensions shown below.
C
A
D
B
FP2530
hearth dims
Figure 2 - 
Hearth Minimum Dimension for Solid Fuel Burning 
Fireplaces and UL127 Factory Built Fireplaces
 
Model 
D
  EYF18 
5" 
13" 
17Z\x" 
17" 
 
   
(635 mm)  (330 mm)  (445 mm)  (433 mm)
  EYF4 w/ 
9" 
13" 
19Z\x" 
17" 
 
  EYF4-(R,F) 
(737 mm)  (330 mm)  (495 mm)  (433 mm)
  EYF4 w/ 
33" 
13" 
5Z\v" 
17" 
 
  EYF30-R 
(838 mm)  (330 mm)  (641 mm)  (433 mm)
FP530
IMPORTANT INFORMATION FOR THE INSTAL-
LATION  OF  THIS  GAS  LOG  SET  IN A  FIRE-
PLACE WITH A RESTRICTIVE BARRIER
The following are guidelines for placing a gas log set in 
a fireplace that has a restrictive barrier along the bottom 
front  opening  of  the  fireplace.  Some  examples  of  barri-
ers  are  glass/screen  door  frames  and  sunken/recessed 
fireplaces.
 
Height of 
Minimum Depth of
 
Restriction (x) 
Fireplace/Firebox
  No Restriction 
13”
  1/” to 1Z\x” 
16”
  Greater than 1Z\x” to 3” 
16”
  Greater than 3” 
*
*Any barrier greater than 3” placed in front of the gas log 
set is not recommended by the manufacturer.
NOTE: Non combustible material such as refractory 
brick may be used to line the floor of the fireplace in 
order to raise the height of the gas log set in relation to 
a restrictive barrier. If the unit is raised, the minimum 
height dimension listed in the homeowner’s manual must 
not be exceeded.
NOTE: If the log set is equipped with a remote receiver, 
a restrictive barrier may reduce the battery life by 
increasing the ambient temperature inside the fireplace. 
Placement of the receiver outside of the fireplace will 
extend the battery life.
Barriers such as the bottom of a glass door 
frame placed in front of a gas log set can 
change  the  air  flow  characteristics  of  the 
fireplace which in turn can cause the unit 
to overheat and malfunction.
W
ARNING
LO
HI
OFF
ON
I
G
N
X
FP2531
fireplace w barrier
Refer to 
Table 1
Glass door frames 
with adjustable 
louvers should 
have the louvers 
fully open while the 
unit is in operation
The log set should 
be placed against or 
as near as possible 
to the rear wall of the 
fireplace/firebox.
Height of restrictive barrier 
caused by glass door frames, 
recessed fireplaces, etc. from 
the base or bottom surface of 
the unit.
FP531
Figure 3 - 
Reference Drawing of a Natural Flame Log 
Set in an Enclosure