INSTALLATION
The dimensions shown in Figures 4 through 10 and defined in the fireplace 
manufacturer's instructions are minimum clearances to maintain when 
installing  this  heater.  Left  and  right  clearances  are  determined  when 
facing the front of the heater.
When heater is installed into a ventless firebox, minimum clearances, 
as specified by the ventless firebox manufacturer, must be met.
Follow these instructions carefully to ensure safe installation. Failure 
to follow instructions exactly can create a fire hazard.
Sidewall and ceiling clearances: The sides of the fire-
place opening must be at least 16" from any combustible 
wall. The ceiling must be at least 42" from the top of the 
fireplace opening. 
16"
42"
FP1996
wall ceiling clearances
Figure 4 - 
Sidewall and Ceiling Clearances
FP1996
Heat resistant material (minimum requirements) with 
no wooden mantel or other combustible projection:
 
To  install  the  gas  logs  into  a  fireplace  with  no  wooden 
mantel,  shelf  or  other  combustible  projection  above  the 
fireplace  opening,  measure  the  heat  resistant  material 
height, per Figure 5, then see TABLE A.
Heat resistant materials such as slate and marble must be 
at least 
1
/2" thick. Sheet metal should not be installed 
onto combustible material.
IMPORTANT:
 If you cannot meet these minimum clear-
ances  you  must  operate  the  heater  with  chimney  flue 
damper  open.  See  Installing  Vented  Applications  found 
on page 16.
W
ARNING
FP2533
mantel clear no hood
Heat 
Resistant 
Material
Measure This 
Distance
Heater in Fireplace 
or Firebox
FP533
Figure 5 - 
Mantel Clearance without Hood
 Heat Resistant Material  EYF24/18 Requirements   
 
Measurement 
for Safe Installation
  0" or more 
Hood not required
  8" to less than 0" 
Extend heat resistant material  
   
to 0" or install hood. Figure 6
  Less than 8" 
Extend heat resistant material  
   
to at least 8" and install hood.   
   
Figure 6. OR, extend heat  
 
   
resistant material to a height   
   
of at least 0".
Table A - 
Heat Resistant Material Requirements with No 
Mantel or Combustible Projection
CLEARANCE and HEIGHT REQUIREMENTS