Harman Stove Company P35I Benutzerhandbuch

Seite von 48
10
Pellets or Corn/Pellet Mixture Only                                           3-90-775                                                                           Save These Instructions
                         P35i Fireplace Insert
B.  Clearances To Combustibles - 
Masonry or Manufactured Fireplace
C.  Floor Protection Requirements
Hearth extension must be of a non-combustible material. It 
must extend beyond the appliance according to the mea-
surements listed. 
Minimum Size Hearth Extension is 16" Deep By 32" Wide. 
Mantel
Side 
W
all
Face Trim
A
B
C
E
D
F
C
D
B
A
Location
Inches
Millimeters
Insert to combustible sidewall
Surround top to face trim
  13            330
    1             25.4
    0               0
   12            305
Surround side to face trim
Insert top to (max) 12" mantel
F
E
Location
Inches
Millimeters
Window opening to front
 6               152
  6               152
Window opening to side
D.  Minimum Opening for Masonry   
      and Manufactured Fireplaces
I
I
H
G
Location
Inches
Millimeters
Minimum Width
 24              609
  23½           597
 14.5           368
  19½           495
Minimum Depth
Minimum Height #1-70-774235  
Minimum Height #1-70-774195
 H
  I
G
The Maximum mantel depth (J) is 12 inches (305 mm) with 
a minimum vertical height (K) of 12 inches (305 mm).
K
J
E.  Mantel Projections
ThE ClEARANCEs spECIfIED ARE fOR yOUR sAfETy!
ThEsE ClEARANCEs mAy ONly bE REDUCED by
mEANs AppROvED by ThE REGUlATORy AUThORITy.