Save These Instructions                                                                    3-90-775                                               Pellets or Corn/Pellet Mixture Only
P35i Fireplace Insert
F.  Factory-Built Fireplace Installation
When  installing  the  P35i  Insert  into  a  factory  built 
wood burning fireplace, several things need to be taken 
into consideration.
The size of the fireplace opening. Will the unit fit into 
the opening? Some of the factory built fireplaces have 
metal smoke shields inside the top that can be removed 
to  gain  height.  Keep  in  mind  that  anything  removed 
from the factory built fireplace must be attached to the 
fireplace with a metal wire. 
Floor protection guidelines, 
as listed previously, must also be followed.  
The manufactured fireplace may not be altered be-
yond the exceptions listed below. Never remove masonry 
bricks or mortar from an existing fireplace.
The following modifications are permissible:
•  Removal of the damper or lock in open position
•  Removal of smoke shelf or baffle
•  Removal of andirons or ember catchers
•  Removal of log grate
•  Removal of view screen or curtain
•  Removal of doors
•  External trim pieces, that do not affect the operation 
of the fireplace, may be removed providing they can 
be stored on or within the fireplace for reassembly if 
the insert is removed.
•  If the hearth extension is lower than the fireplace 
opening, the portion of the insert extending onto the 
hearth must be supported.
•  Final approval of this type of installation is contingent 
upon the authority having jurisdiction.
Note: If the Harman P35i Insert is installed into a factory built wood burning fireplace, this 
label (Harman part #  3-90-00675) MUST be attached to the altered fireplace. 
The factory built chimney must be listed per UL 127 (US) 
and meet type HT requirements of UL 103 (US).  Factory 
Built fireplace chimneys tested to UL 127-98 may be, at the 
fireplace manufacturers option, tested to the same criteria 
as UL 103HT requirements.  If the chimney is not listed as 
meeting HT requirements, or if the factory built fireplace was 
tested prior to 1998, a full height listed chimney liner must 
be installed from the appliance flue collar to the chimney top.  
Liner must meet high temperature (2100 F) per UL1777 (US).  
The liner must be securely attached to both the flue collar 
and the chimney cap. To prevent room air passage to the 
chimney cavity of the fireplace, seal the damper area around 
the chimney liner with fiberglass batting.
Hearth must be constructed to 
the proper height and finished 
with a non-combustible 
material.
IN CANADA: This fireplace insert 
must be installed with a continuous 
chimney liner of a minimum 3" 
diameter extending from the insert to 
the top of the chimney. The chimney 
liner must conform to the Class 3 
requirements of CAN/ULC-S635, 
Standard for Lining Systems for 
Existing Masonry or Factory Built 
Chimneys and Vents, or CAN/ULC-
S640, Standard for Lining Systems 
for New Masonry Chimneys.
When using single-wall 
venting or flex,this section 
of venting must be wrapped 
with a non-combustible 
insulation to prevent excess 
temperatures within the 
fireplace and on the fuel 
hopper.