Pellets or Corn/Pellet Mixture Only                                           3-90-775                                                                           Save These Instructions
                         P35i Fireplace Insert
7
 
Appliance Set-Up
A.  Outside Air Attachment
Outside Air Kit #1-00-774280 (sold separately) must 
be used for attaching outside air to the insert. This kit 
contains a 3" stub and gasket to mount to the frame, 
and the outside air adapter which secures to the insert 
body. The outside air intake connection will seal to the 
mounting frame, just like the exhaust does. Follow the 
instructions included in the kit to ensure proper instal-
lation.
1.  Make a determination of where you want to draw 
the outside air from. Here are a few options.
 
a. Punch a hole through the rear of the 
                fireplace and exterior wall. Rigid pipe or flex
                pipe could be used.
 
b. Use the chimney or chase as a conduit for   
                outside air. The exhaust liner must be run    
                the full length of the flue. When creating      
                your steel plate to seal the damper area,
 
    Make another 3 inch hole for the outside air
 
    pipe. Install a short run of pipe from the        
                mounting frame through the sealing plate.  
 
    Then install the chimney top extension kit,
 
    item #1-00-674104 at the top of the chimney.
 
    This is slotted to allow fresh air into the      
                chimney or chase.
2.   Secure the outside air supply pipe to the stub on   
      the mounting frame using a minimum of two fas-   
      teners.
3.   If running the supply pipe direct, install the outside
      air cover weldment #1-10-09542 to keep birds or
      rodents from entering the supply pipe. 
4.   Keep the intake a minimum of 4 feet (1.2 m) below    
      the exhaust termination.
CAUTION!
Never draw outside combustion air from:
•  Wall, floor or ceiling cavity.
•  Enclosed space such as an attic or garage
The image at left shows the use of the chim-
ney for outside air supply. Also shown is the 
Chimney intake extension on the top of the 
chimney. It is slotted to allow fresh air into 
the flue. Be sure to use the proper flashing 
and vent cap to prevent rain from entering the 
chimney flue.
The image below demonstrates bringing the 
outside air in through a hole cut through the 
rear of the fireplace and external wall. With 
this method, a screen is necessary to prevent 
birds or rodents from entering. 
Outside Air Intake 
Weldment
Intake Stub
Stub Gasket
Stub Mounting 
Bolts
Self- drilling 
screws (2)
Contents of Outside Air Kit
--
--