Save These Instructions                                                                    3-90-775                                               Pellets or Corn/Pellet Mixture Only
P35i Fireplace Insert
Room sensor placed here gives an accurate measure of return air. 
Push the pre-cut hole inward, and feed the sensor from the back 
side. Allow the bulb of the sensor to extend approximately 1½ 
inches into the room. Use a wire tie on the push-in tab to secure 
the sensor wire.
G.  Control Board Installation
The control board is packaged in a static resistant 
bag. Use care when handling, hold the circuit board 
only by the edges. In a large fireplace opening, you 
may have plenty of space for the circuit board to re-
main attached. For a smaller fireplace opening, you'll 
likely need to remove the wiring from the circuit board 
to route it through the side of the mounting frame and 
out through the control opening. Follow these steps;
•  Disconnect the 11 pin harness plug.
•  Disconnect the red twisted ESP wire. 
•  Feed the harness wires and the ESP wire through 
the opening in the mounting frame and out 
through the control opening in the surround panel.
•  Holding the control board outside the opening in 
the surround panel, re-attach the harness plug 
and the ESP wire. 
•  After determining the location of the Room Sen-
sor (See next Section), Attach it to the two male 
spade terminals near the top of the circuit board.
 NOTE: These connections are not polarity specific.
•  From the power cord, attach the green ground 
wire to the grounding post located on the feeder 
air intake snout.
•  The black wire from the power cord gets attached 
to the short brown wire from the control harness
•  The white wire from the power cord will attach to 
the short white wire on the control harness.
•  Install the control panel into the surround; Right 
side first, then tilt in the left side.
•  Secure using the four black machine screws in-
cluded with the surround.
H.  Room Sensor Installation
Although not required, it is recommended that the 
room sensor be connected in every installation. Using 
a minimum size 18 gauge wire, you may splice in an 
additional length, to extend the room sensor. The fol-
lowing are typical locations for the room sensor;
•  On an interior wall next to or in place of a typical 
wall thermostat.
•  On the leg of a coffee table or end table in your 
favorite sitting location.
•  Sticking out through the punched hole at the lower 
right corner of the control panel.
Note: When installing the room sensor externally, 
limit the distance from the stove to 25 feet or less. 
Once the location has been decided, run the wiring to 
the control panel. You'll need to remove the two ter-
minals from the end of the sensor cable and replace 
them with the two smaller terminals from the hardware 
bag. Plug the terminals into the circuit board. These 
connections are not polarity specific.
Note: If the room sensor is located too close to 
the appliance, or in a direct path of the distribu-
tion air, You may need to elevate the temperature 
setting to maintain a comfortable temperature 
level throughout the heated space.
        See Draft Test Procedure on Page 26.
F.  Installing the Body into the 
Mounting Frame
The rollers on the sides of the insert body will ride on 
the rails of the mounting frame. Once the body is all 
the way in, hook and close the top spring latches on 
each side to secure.