Goodman Mfg SS-CPC90-150 Benutzerhandbuch

Seite von 36
P
roduct
 S
PecificationS
P
roduct
 S
PecificationS
2 www.goodmanmfg.com 
SS-CPC90-150
n
omenclature
 
C
P
C
150
045
3
B
X
X
X
1
2
3
4,5,6
7,8,9
10
11
12
13
14
Brand
Factory-­‐Installed  Op;ons
C
Commercial
X
No  Op:ons
A
Non-­‐powered  convenience  outlet
Configura;on
B
Powered  convenience  outlet
P
Packaged  Unit
C
Low-­‐ambient  kit
F
Non-­‐powered  convenience  outlet;  
Applica;on
Low-­‐ambient  kit
C
Cooling
M Powered  convenience  outlet;
G
Gas  Heat
Low-­‐ambient  kit
H
Heat  Pump
Factory-­‐Installed    Op;ons
Nominal  Gross  Cooling  Capacity  
X
Standard  Aluminized  Heat  Exchanger  
036
3  Tons
102
8½  Tons
A
Condenser  Coil  Hail  Guard
048
4  Tons
120
10  Tons
B
Condenser  Coil  Hail  Guard
060
5  Tons
150
12½  tons
Treated  Condenser  Coil  (UltraGold)
072
6  Tons
180
15  Tons
C
Condenser  Coil  Hail  Guard
090
7½  Tons
240
20  Tons
Stainless  Steel  Heat  Exchanger
D
Condenser  Coil  Hail  Guard
Nominal  Hea;ng  Capacity
Treated  Condenser  Coil  (UltraGold)
CPG  
CPC/CPH  (Factory-­‐Installed  Electric  Heat)
Stainless-­‐Steel  Heat  Exchanger
045
   45,000  BTU/h
XXX
No  Heat
J
Treated  Condenser  Coil  (UltraGold)
090
   90,000  BTU/h
010
10  kW
030 30  kW
S
Stainless-­‐Steel  Heat  Exchanger
115
115,000  BTU/h
015
15  kW
031 30  kW
T
Treated  Condenser  Coil  (UltraGold)
140
140,000  BTU/h
016
15  kW
045 45  kW
Stainless-­‐Steel  Heat  Exchanger
210
210,000  BTU/h
018
18  kW
046 45  kW
350
350,000  BTU/h
020
20  kW
060 60  kW
Factory-­‐Installed  Op;ons
400
400,000  BTU/h
025
25  kW
075 75  kW
X
No  Op:ons
A
Downflow  Economizer
Voltage
Supply  Fan/Drive  Type/Motors
1
208V  1-­‐Phase
4 460V  3-­‐Phase
B
Belt  Drive
2
220/240V  1-­‐Phase  50  Hz
5 380/415V  3-­‐Phase  50  Hz
D
Direct  Drive
3
208/230V  3-­‐Phase
7 575V  3-­‐Phase
H
High-­‐Sta:c  Belt  Drive  (Factory-­‐Installed)
Factory-­‐Installed  Op;ons
Condenser  Hail  Guards:  Louvered  metal  guards  help  protect  the  condenser  coil  from  damage  from  hail  and  debris.    Available  as  a  factory-­‐installed  op:on  
on  3-­‐  to  12½-­‐ton  units.  Hail  guards  are  standard  on  15-­‐  and  20-­‐ton  units.
Stainless-­‐Steel  Heat  Exchanger  (CPG  units  only):  A  tubular  heat  exchanger  made  of  409-­‐type  stainless  steel  is  installed  in  the  unit.
Ultra-­‐Gold  Condenser  Coil:  Offers  increased  corrosion  resistance  of  the  condenser  coil.
Low-­‐Ambient  Kit:  Allows  for  cooling  opera:on  at  lower  outdoor  temperatures.  On  the  3-­‐  to  6-­‐ton  units,  cooling  opera:on  is  extended  from  60°F  ambient  temperature  
to  35°F  outside  air  temperature.  On  7½-­‐  to  20-­‐ton  units,  cooling  opera:on  is  extended  from  35°F  ambient  temperature  to  0°F  outside  air  temperature.      
Economizers  (Downflow):  Based  on  air  condi:ons,  can  provide  outside  air  to  cool  the  space.
High  Sta:c  Kits:  Provides  airflow  in  higher  sta:c  applica:ons.
Electric  Heat  Kits  (CPC  and  CPH  units  only):  Available  in  all  voltage  op:ons.
Non-­‐powered  Convenience  Outlet:  A  120V,  15A,  GFCI  outlet  makes  it  easier  for  technicians  to  service  the  unit  once  an  electrician  runs  power  to  the  outlet.
Powered  Convenience  Outlet:  A  120V,  15A,  GFCI  outlet  powered  with  a  transformer  built  into  the  unit.