Initial Installation
QUALIFIED INSTALLERS ONLY
E
LECTRICAL
 R
EQUIREMENTS
:
The  fan  is  thermostatically  controlled  and 
it  will  not  operate  if  the  appliance  is  cold. 
A few minutes after the appliance is lit and 
the variable speed control is set at a desired 
setting, the fan will automatically turn on. 
The fan will automatically turn off after the 
appliance has cooled down.
The fireplace must be electrically grounded 
in  accordance  with  local  codes  or,  in  the 
absence  of  local  codes,  with  the  current  
Canadian Electrical Code CSA C22.1, or The 
National Electrical Code ANSI / NFPA 70 in 
the US. This appliance must be connected 
to a line-voltage electrical supply.
WARNING:  The  electrical  grounding 
instructions  must  be  followed.  The  fan  kit 
is equipped with a three-prong (grounding) 
plug  for  your  protection  against  shock 
hazard, and should be plugged directly into 
a properly grounded three-prong outlet. DO 
NOT  cut  or  remove  the  grounding  prong 
from this plug.
COOL / HEAT
PROGRAM
DOWN
UP
70 ° F
70 ° F
ON
OF
F
Optional
Remote
Control
Purple
Grey
Optional
Wall Switch
Optional
Thermostat
Pilot
Adjustment
Screw
ON/OFF/REMOTE
Thermostat Switch
Blue
Thermopile
Thermocouple
Manifold
Pressure
Tap
Inlet
Pressure
Tap
Gas
Control
Valve
Blue
BV Only
300
o
F (149
o
C)
Temperature
Sensor
(DV has only
connectors)
Figure 23: Wiring of a valve and thermostat.
Table 4.  Recommended Thermostat 
Wire Size.
Wire Size
Max. Length
14 gauge
100 ft  (30.48 m)
16 gauge
60 ft   (18.29 m)
18 gauge
40 ft   (12.00 m)
20 gauge
25 ft   (7.62 m)
22 gauge
18 ft   (5.49 m)
Figure 22: Fan wiring diagram.
CAUTION:  Label  all  wires  prior 
to  disconnecting  when  servicing 
controls.    Wiring  errors  can  cause 
improper and dangerous operation. 
Verify  proper  operation  after 
servicing.