Multiquip DCA220SSCU4i Benutzerhandbuch

Seite von 90
page 36 — dca220sscu/4i 60 hz generaTor • operaTion and parTs manual — rev. #0 (10/25/12) 
*
1
  Replace engine oil and filter at 100 hours, first time only.
*
2
  Add “Supplemental Coolant Additives (SCA’S)” to recharge the engine coolant.
*
Replace primary air filter element when restriction indicator shows a vacuum of 625 mm (25 in. H20).
*
If blowby hose needs to be replaced, ensure that the slope of the blowby hose is at least a 1/2 inch per foot, 
with no sags or dips that could collect moisture and/or oil. 
Table 12. inspection/maintenance
10 hrs 
dailY
250 hrs 500 hrs
1000 
hrs
engine
Check Engine Fluid Levels
X
Check Air Cleaner
X
Check Battery Acid Level
X
Check Fan Belt Condition
X
Check for Leaks
X
Check for Loosening of Parts
X
Replace Engine Oil and Filter * 
1
X
Clean Air Filter
X
Check Fuel Filter/Water Separator Bowl
X
Clean Unit, Inside and Outside
X
Change Fuel Filter 
X
Clean Radiator and Check Coolant Protection Level*
2
X
Replace Air Filter Element * 
3
X
Check all Hoses and Clamps * 
4
X
Clean Inside of Fuel Tank
X
generator
Measure Insulation Resistance Over 3M ohms
X
Check Rotor Rear Support Bearing
X
MaiNteNaNCe
general inspecTion
Prior to each use, the generator should be cleaned and 
inspected  for  deficiencies.  Check  for  loose,  missing  or 
damaged  nuts,  bolts  or  other  fasteners.  Also  check  for 
fuel,  oil,  and  coolant  leaks.  Use Table  12  as  a  general 
maintenance guideline 
engine side (Refer to the Engine 
Instruction Manual)
air cleaner
Every 250 hours: Remove air cleaner element (Figure 55) 
and clean the heavy duty paper element with light spray of 
compressed air. Replace the air cleaner as needed. 
air cleaner with dust indicator
This indicator () is attached to the air cleaner. When the air 
cleaner element is clogged, air intake restriction becomes 
greater and the dust indicator signal shows 
red meaning 
the  element  needs  changing  or  service.  After  changing 
the air element, press the dust indicator button to reset 
the indicator.
Figure 55. Air Cleaner/Indicator
NOTICE
The air filter should not be changed until the indicator 
reads 
“red”. Dispose of old air filter. It may not be 
cleaned or reused..