Quattro DC Interconnections 
 
 
 
 
 
 
 
 
 
 
 
 
 
18 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 6: Logic Inputs (External Supply) 
 
Analog Inputs 
The Quattro DC has two non-programmable 
differential analog input channels.   
•  Analog input channel 1 is reserved for the 
speed command (if used).   
•  Analog input channel 2 is reserved for the 
pre-torque command (if used) or torque 
command source (if used). 
The analog input channels are bipolar and have 
a voltage range of 
±10VDC.  
Available with the analog channels is multiplier 
gain parameters (SPD COMMAND MULT and 
EXT TORQUE MULT) and bias parameters 
(SPD COMMAND BIAS and EXT TORQUE 
BIAS). These parameters are used to scale the 
user’s analog command to the proper range for 
the drive software.  The formula below shows 
the scaling effects of these two parameters.     
uses
software
drive
signal
MULT
BIAS
voltage
input
channel
analog
=
×
 
For more on the multiplier gain or bias 
parameters, see Drive A1 submenu on page 30. 
The scaling of the analog input signals, with 
BIAS set to 0.00 and MULT set to 1.0 follows: 
•  Speed Command  
+10VDC = positive contract speed 
-10VDC = negative contract speed 
•  Pre Torque Command  
+10VDC = positive rated pre-torque of motor 
-10VDC =
 
negative rated pre-torque of motor 
•  Torque Command  
+10VDC = positive rated torque of motor 
     -10VDC =
 
negative rated torque of motor 
NOTE: The drive cannot recognize voltages 
outside of the 
±10VDC on its analog input 
channels. 
The Quattro DC provides common mode noise 
rejection with the differential analog inputs.  The 
connection of these two differential inputs is 
shown in Figure 7. 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 7: Analog Inputs (Differential)
 
Figure 8 shows the connection for the analog 
inputs if they are configured for single-ended 
connection.   In this configuration, the Quattro 
DC noise immunity circuitry is not in effect.  
Note: For prevention of ground noise 
interference, a twisted shielded pair must be run 
to the source and not connected at the board. 
 
 
 
 
 
 
 
 
 
 
 
 
 
PreTorque  
Cmd, ±10V 
or Torque 
Command, ±10V
 
15 
 
16 
 
18 
 
19 
 
17 
analog input 1+
analog input 1-
analog input 2+
analog input 2- 
analog input common 
TB1 
Speed Cmd 
±10V 
 
 
19 
PreTorque  
Cmd, ±10V 
or Torque 
Command, ±10V
 
 
15 
 
 
16 
 
 
18 
 
 
17 
analog input 1+
analog input 1- 
analog input 2+
analog input 2- 
analog input common 
TB1 
Speed Cmd 
±10V
+24V external 
supply 
Contact 
Cfirm 
A9JCC1-2 
A9JCC1-1 
A9TB1 
11 
logic input 1 
logic input 2 
TB1 
Figure 8: Analog Inputs (Single Ended)
 
2
 
+24VDC isolated 
10 
43 
46 
44 
logic input common 
C_24VISO 
+24VDC isolated 
C 24VISO
5
 
logic input 3 
logic input 4 
logic input 5 
logic input 6 
logic input 7 
logic input 8 
logic input 9 
45 
C 24VISO
CTR PWR Sense 
+