Magnetek TM7310rev01 Benutzerhandbuch

Seite von 126
Quattro DC Interconnections 
 
19 
 
Logic Outputs 
The Quattro DC’s seven programmable logic 
outputs are opto-isolated, open collector.  The 
outputs are normally open and can withstand an 
applied maximum voltage of 30VDC.  When the 
outputs become “true”, the output closes and is 
capable of sinking up to 150mA between the 
logic output terminal and the logic output 
common (TB1-32).  Figure 9: Logic Outputs 
shows the logic output terminals. 
Note: Logic Output 1 is prewired for CLOSE 
CONTACT. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 9: Logic Outputs
 
For more information on programming the logic 
outputs, see Logic Outputs C3 submenu on 
page 63. 
 
Relay Outputs 
The Quattro DC’s two programmable relay logic 
outputs are Form-C relays.  The have both 
normally open and normally closed contacts.   
The specifications for each relay are as follows: 
Relay 1 
•  2A at 30VDC or 1A at 230VAC 
Relay 2 
•  2A at 30VDC or 1A at 230VAC 
 
 
 
TB1 
47 
48 
25 
26 
27 
28 
29 
30 
31 
32 
33 
45 
+24V iso. 
+24V iso. 
logic output 1 
A9JCC1-3 
logic output 2 
logic output 3 
logic output 4 
logic output 5 
logic output 6 
logic output 7 
 
 
 
 
 
 
 
 
 
 
Figure 10: Relay Outputs
 
For more information on programming the relay 
outputs, see Logic Outputs C3 submenu on 
page 63. 
Solid State Relay Outputs 
The Quattro DC has two programmable solid-
state relays. They have a 30 VDC max with 
150mA load capability. 
Figure 11: Solid State Relay Outputs shows the 
relay output connections. 
 
 
 
 
 
 
 
 
 
Figure 11: Solid State Relay Outputs 
For more information on programming the solid-
state relays, see Logic Outputs C3 submenu on 
page 63. 
+24V iso. common 
+24V iso. common 
logic output common 
relay 1
TB2 
relay 2
10 
12 
23 
21 
22 
24 
solid state relay 1
TB1 
solid state relay 2