 Chapter 3: EDH-6800-2 EDH Detection/Insertion Serial Distribution Amplifier Module
Controls, Indicators, and Jumpers
30
 6800/7000 Series - Distribution and Routing Products Installation and Operation Manual
Jumpers
Jumper
Description
525/625
Forces the line standard to 525, 625, or auto.
This jumper allows you to set the EDH-6800-2 
configuration to the known line standard of either 525 or 
625. 
Removing the jumper puts the module in Auto mode. In 
Auto Line Standard
 mode, the EDH-6800-2 automatically 
detects the line standard and configures accordingly. 
This jumper is only active if the Remote jumper is set to EN.
FF/AP
Selects the FF or AP region.
This jumper allows you to select the error (Active Picture 
or Full Field) which will activate the Alarm LED, the 
audible alarm, and the fault reporting opto-isolated output. 
This jumper is only active if the Remote jumper is set to EN.
Remote EN/
DIS
Enables the Remote.
EDH-6800-2 can support three external control interfaces:
• Local - module-edge LED, jumpers, and switches
• Network - remote control network interface (DigiNet)
• Front Panel - MIXBOX front panel interface
• The Remote EN/DIS jumper, in concert with automatic 
front-panel detection, places the EDH-6800-2 into one 
of the following modes:  
EDH On/Off
Enables EDH processing or bypass mode.
This jumper enables EDH processing (if On) or places 
EDH-6800-2 into bypass mode (if Off). In bypass mode, 
the EDH-6800-2 acts as a simple DA, and both input EDH 
analysis and output EDH generation are disabled.
Remote 
Jumper
Front Panel 
Detected
Control Mode
DIS
NO
LOCAL only
DIS
YES
FRONT PANEL only
EN
NO
NETWORK only
EN
YES
NETWORK and FRONT PANEL