Nokia 7000 Series Benutzerhandbuch

Seite von 151
 6800/7000 Series - Distribution and Routing Products Installation and Operation Manual
31
Controls, Indicators, and Jumpers
 Chapter 3: EDH-6800-2 EDH Detection/Insertion Serial Distribution Amplifier Module
FR_ID On/Off  Selects between external 9000SSN Frame ID or fault 
opto-isolated output.
When set to On, EDH-6800-2 will attempt to read the 
Frame ID from the 9000SSN silicon serial number device at 
the FR-680X series frame RJ11 connector. When set to Off
the EDH-6800-2 will use the RJ11 connector for the fault 
reporting output (see page 32.) When both jumpers are 
removed, the EDH-6800-2 is isolated from the RJ11 
connector. If EDH-6800-2 does not detect the 9000SSN 
device (if none is present at the RJ11 or if FR-ID is Off), 
EDH-6800-2 will attempt to use the dual hex Frame ID 
switches (SW4 and SW5) to determine Frame ID.
Jumper
Description
Both jumpers (J5 and J8) must 
be configured identically. And 
all EDH-6800-2 (and similar) 
modules in the same frame 
must be configured identically 
(FR-ID On or Off).