 Chapter 3: EDH-6800-2 EDH Detection/Insertion Serial Distribution Amplifier Module
Fault Reporting Output
32
 6800/7000 Series - Distribution and Routing Products Installation and Operation Manual
Fault Reporting Output
The fault-reporting optically-isolated output is accessible at the rear RJ11 
connector of the FR-680X series frame. RJ11 pins 3 and 4 are used as 
negative and positive terminals respectively. 
The output is open when no errors are occurring, is closed with frame 
power removed, and pulses closed for the duration of a field with EDH 
errors (as configured by the FF/AP jumper). 
Figure 3-2 illustrates a basic interface:
Figure 3-2. 
Fault Reporting Output