Emerson Network Router Benutzerhandbuch
96
ProLink
®
II Software for Micro Motion
®
Transmitters
Configuring the Discrete Batch Application
Inhibit Batch and Inhibit Totalizer processing
If the Inhibit Batch function is mapped to a discrete input:
•
When that discrete input is in the active state:
-
A batch cannot be started.
-
A Start Not Okay alarm is posted if starting a batch is attempted.
•
If the discrete input then becomes inactive, the batch does not start automatically.
•
If a batch is already running when the discrete output becomes active, the batch is not affected.
If the Inhibit Totalizer function is mapped to a discrete input:
•
The totalizer will not increment while the discrete input is active.
•
The totalizer will resume incrementing automatically when the discrete input becomes
inactive.
inactive.
•
If the discrete input is inactive, the totalizer is active, whether or not a batch is running. Even if
a batch is not running, the totals will be incremented if flow is detected.
a batch is not running, the totals will be incremented if flow is detected.
Table B-4
Batch control assignments
Function
Default
assignment
assignment
Assignment options
ON state actions
End discrete
batch
batch
None
Specify the method that will
be used to perform the batch
control function:
be used to perform the batch
control function:
• None
• Discrete input 1
• Discrete input 2
• Discrete event 1
• Discrete event 2
• Discrete event 3
• Discrete event 4
• Discrete event 5
• Discrete input 1
• Discrete input 2
• Discrete event 1
• Discrete event 2
• Discrete event 3
• Discrete event 4
• Discrete event 5
• Ends the batch.
• The batch cannot be resumed.
• The batch totalizer must be reset for the next
• The batch cannot be resumed.
• The batch totalizer must be reset for the next
batch.
Inhibit discrete
batch
batch
• Batch cannot be started.
• Inhibit batch is used for temporary lockout. See
• Inhibit batch is used for temporary lockout. See
Inhibit discrete
batch totalizer
batch totalizer
• Delivers the batch but does not totalize.
• Inhibit totalizer is used when process fluid is
• Inhibit totalizer is used when process fluid is
recirculated. See Section .
Reset discrete
batch
batch
• Resets batch total to zero.
• Batch reset cannot be performed while a batch is
• Batch reset cannot be performed while a batch is
running or while a batch is stopped. Before a
batch can be reset, the batch target must be
reached or the batch must be ended.
batch can be reset, the batch target must be
reached or the batch must be ended.
• The batch controller can be configured to reset
automatically on start. To configure Reset on
start, see Section B.3.2.
start, see Section B.3.2.
Resume discrete
batch
batch
• Resumes a batch that has been stopped.
• Counting resumes from the total at which the
• Counting resumes from the total at which the
batch was stopped.
Start discrete
batch
batch
Starts the batch by opening the flow control valve(s)
and/or starting the pump.
and/or starting the pump.
Stop discrete
batch
batch
• Stops the batch.
• The batch can be resumed if the batch total is
• The batch can be resumed if the batch total is
less than the batch target.
• If lockout target is disabled as a control option, the
operator can change the target before resuming.
• To enable or disable lockout target, see
Increment
current batch
preset
current batch
preset
Selects next configured preset (as listed in the
preset menus) for use in the next batch.
preset menus) for use in the next batch.