Commissioning (software) 
 
4.9 Testing the configured drive using the drive control panel 
D410 
Commissioning Manual, 08/2008 Edition 
109
 
4.9 
Testing the configured drive using the drive control panel 
You can test a configured drive using the drive control panel where you can define a speed 
value by setting a scaling factor. The drive control panel should only be used for 
commissioning.  
Prerequisites 
●  The project has been downloaded to the target system. 
●  SIMOTION SCOUT is in online mode. 
●  The drive is not in use by a current project in RUN mode. 
 
WARNING 
 
 
Make sure that the drive test does not pose any risk to persons. 
Testing the drive using the drive control panel 
1.  Change to the configured drive in the Project Navigator and open the drive control panel 
by selecting "Commissioning" > "Control panel". The drive control panel opens in the 
detail view. 
 
Figure 4-28  Drive control panel 
 
2.  In order to view the control range and axis diagnostics data, click "Show/hide control" and 
Show/hide axis diagnostics". 
3.  Click "Assume control priority". The "Assume Control Priority" dialog box opens.