Commissioning (software) 
 
4.12 Deleting data 
 
D410 
118
 
Commissioning Manual, 08/2008 Edition 
Deleting user data 
1.  Open the project you want to edit in SIMOTION SCOUT. 
2.  Go online to SIMOTION D410. 
3.  Select SIMOTION D410 in the Project Navigator, and then select the "Delete user data 
on card" option from the "Target system" menu. 
4.  Confirm the "Delete user data from card" message with "OK". 
The user data are deleted. SINAMICS Integrated goes into offline mode. 
4.12.4 
Restoring the default settings of SINAMICS Integrated 
Prerequisite 
You must be online to SINAMICS Integrated in order to restore its default settings.  
Restoring the default settings 
1.  Right-click "SINAMICS_Integrated" in the Project Navigator. 
2.  Select the "Target device > Restore default settings" command from the shortcut menu. 
This restores the delivery state of SINAMICS Integrated. 
4.12.5 
Restoring the default settings of SIMOTION D410 
Overview 
SIMOTION D410 is supplied with default parameters such as the transmission rate or 
PROFIBUS addresses. You can restore the default settings using the DIL switch. This 
deletes the following data:  
●  Non-volatile data in the SIMOTION device 
●  The backup copy of non-volatile data on the CompactFlash Card 
(PMEMORY.XML/PMEMORY.BAK) 
●  User data in the "volatile data" area and on the CompactFlash Card 
●  The communication configuration (IP and DP parameters) 